Furuno MARINE RADAR 1823C User Manual

Page 34

Advertising
background image

1-24

7. Pass the antenna cable with connector through the cable gland, gasket and cable

entrance of the antenna unit, and then tighten cable gland.


Note 1: Be sure the shrink tube on the antenna cable does not contact to the gasket.
Note 2: Close the gasket tightly to insert into the cable entrance. Confirm that there is no

space between both ends of the gasket after inserting into the cable entrance.

Rubber gasket

Gasket

Cable Gland

Sectional view

Mounting base

Rubber gasket

Antenna cable

Gasket

Close the gasket
tightly.

Shrink tube

Do not contact
the shrink tube
and gasket.

Antenna unit, inside view


8. Twist antenna connector cables at the position between the shrink tube and the cable tie,

and then attach EMI core (supplied) to cables as follows.

After attachment, shift EMI core slightly to confirm that it does not pinch cables.

Cable tie

Shrink tube

Attach EMI core.

Gasket

Radome base

Twist cables here.

Location of EMI core