(m

3

/hr)

FAN MOTOR

POWER SOURCE

(V)

230

DISCRIMINATION

MFA-45DZM

HI-SPEED

(r.p.m.)

1,000

INDOOR UNIT

MED-SPEED

(r.p.m.)

900

LO-SPEED

(r.p.m.)

750

OUTDOOR

DISCRIMINATION

MFB-30PTT X 2

UNIT

HI-SPEED

(r.p.m.)

780

2005.07.29

1

SPECIFICATIONS

TYPE

COOLING

COOLING & HEATING

INDOOR UNIT

RY-36FA

RY-36UA

OUTDOOR UNIT

RO-36FA

RO-36UA

COOLING CAPACITY

(kW)

10.5

HEATING CAPACITY

(kW)

-------

11.80

POWER SOURCE

FREQUENCY

50Hz

COOLING

6.20

5.90

RUNNING CURRENT (A)

HEATING

-------

6.20

INPUT WATTS

(kW)

COOLING

3.74

3.48

HEATING

-------

3.45

E.E.R.

(kW/kW)

COOLING

2.81

3.02

HEATING

-------

3.42

MOISTURE REMOVAL

4.0

AIR CIRCULATION

1,660

TYPE

Hermetic type, 2 poles, 3 phase,

Twin Rotary

DISCRIMINATION

5JD420PAA02

ELECTRICAL DATA

COMPRESSOR

( /hr)

ADDITIONAL REFRIGERANT CHARGE (R410A)

PIPE LENGTH

20 m

2,000 g

3,200 g

FULL CHARGE

30 m

2,300 g

3,500 g

AMOUNT

40 m

2,600 g

3,800 g

50 m

2,900 g

4,100 g

ADDITIONAL CHARGE

30 g/m

MAX PIPE HEIGHT

30

MAX PIPE LENGTH

(m)

(m)

50

INDOOR UNIT

H x W x D

(mm)

H x W x D

(mm)

240 x 1,660 x 700

OUTDOOR UNIT

1,165 x 900 x 330

DIMENSIONS

INDOOR UNIT

GROSS / NET

GROSS / NET

(kg)

(kg)

61 / 48

OUTDOOR UNIT

87 / 80

101 / 94

WEIGHT

3N 400V