3 adding and deleting network bridges with sac, 1 adding a new sac network bridge, Adding and deleting network bridges with sac – Fortress Technologies ecure Wireless Access Bridge User Manual

Page 121: Adding a new sac network bridge

Advertising
background image

Fortress Bridge: Command-Line Interface

111

SeriallNum|IpAddress|CfgID|PeerNum|PeerSACStatus|PeerSACState|PeerSACVer
24773196|172.24.0.4|19082|2|SAC_PEER_CONFIRMED|

SAC_COMPLETE_4PEER

|SAC_VER_PEGASUS_ARCH1

24743196|172.24.0.3|19082|1|SAC_PEER_CONFIRMED|

SAC_COMPLETE_4PEER

|SAC_VER_PEGASUS_ARCH1

To save the new configuration, enter

set sac stop

:

[GW]>

set sac stop

SAC Stop Initiated. May take some time to complete...
Stopped SAC process successfully
Reboot_Of_Master(SrlNum:24656196)_Required_For_NewConfiguration(CfgId:42550)_To_Take_Into_Effect
Reboot_Of_SACPeer(SrlNum:24773196)_Required_For_Configuration_Change_From(OldCfgId:19082)_To(New
CfgId:42550)_To_Take_Into_Effect
Reboot_Of_SACPeer(SrlNum:24743196)_Required_For_Configuration_Change_From(OldCfgId:19082)_To(New
CfgId:42550)_To_Take_Into_Effect

As the output informs you, you must reboot the Bridges in the
network for the new configuration to take effect.

SAC commands are valid only in Gateway mode (refer to
Section 6.1.1 for more detail).

6.8.3

Adding and Deleting Network Bridges with SAC

6.8.3.1

Adding a New SAC Network Bridge

Once a network has been configured through SAC, you can
use the SAC function to add a new Fortress Bridge to the
network.

1

Position the new Bridge so that it operates only within its
safe temperature range (14º–122º F/

10º–50º C).

2

Connect an 802.11a-capable antenna to antenna port 2
(

ANT2

) of the new Bridge.

3

Connect the

WAN

port of the new Bridge to the

WAN

port of

any node in the SAC network.

4

Connect the new Bridge’s external +48V DC power supply
to its front-panel

+48V DC

power inlet, and plug the power

supply into a properly rated AC power outlet with the cord
provided.

NOTE:

An RJ-45-

to-DB9 adapter—

included with each
Bridge—is required to
connect the Bridge’s se-
rial

Console

port to a

DB9 terminal connec-
tion. Pin outs for these
adapters are given in
Table 7.1 on page 116.

5

Connect the new Bridge’s

Console

port directly to the serial

terminal of the computer you will use to preconfigure the
new Bridge.

6

Open a terminal application on the computer connected to
the new Bridge’s

Console

port and (using the settings given

in Section 6.1.2) open a session with the new Bridge.

7

Log in to the CLI of the new Bridge, using

sysadm

as both

the login ID and password.

8

Preconfigure the new Bridge to use the same Access ID
and encryption algorithm already in effect on the Fortress
Bridge network with these commands:

[GW]>

set accessid <16digithexid>

[GW]>

set crypto [-e aes128|aes192|aes256][-t <hrs>]

9

Use

show sac

to determine—and then make a note of—the

serial number of the new Bridge: