Overcurrent Protection Circuit: Range of Operation

When an overcurrent flow occurs, if the increased voltage between the drain and source of the FET is detected
by means of the external FET (Q1) resistor, operational stability is lost when the external FET (Q1) ON interval
determined by the oscillation frequency, input voltage, and output voltage falls below 450 ns.

Therefore, the circuit should be used within a range that ensures that the ON interval does not fall below 450ns,
according to the following formula.

If the ON interval of the external FET (Q1) is below 450ns, we recommend the use of an overcurrent detection
resistor RS to detect overcurrent, as shown below.
This example shows the range of operation of the overcurrent detection function with a setting of Vo = 3.3V.

ON interval 450 (ns)

V

O

(V)

V

IN

(V)

× f

OSC

(Hz)


+

20

4

21

ILIM1

(ILIM2)

VS1

(VS2)

V

IN

Error Amp

Q1

5

(Rs)

1600

1400

1200

1000

800

400

200

0

6

8

10

12

14

VCC (V)

f

OSC

(kHz)

16

18

20

Overcurrent Detection Function Operating Range

V

O

= set to 3.3 V

Operation Range

• Method to detect by current when external FET(Q1) is turned on

Connect to RS

when

using RS


+

20

4

21

ILIM1

(ILIM2)

VS1

(VS2)

VIN

R

S

Error Amp

Q1

5

1600

1400

1200

1000

800

600

400

200

0

6

8

10

12

14

VCC (V)

f

OSC

(kHz)

16

18

20

Overcurrent Detection Function Operating Range

V

O

= set to 3.3 V

Operation Range

Method to detect by mean current

(

Possible to detect at 2 V or more of output voltage

)