Wiring, Power cable, Display unit, rear view – Furuno GP-1850WD User Manual

Page 13: Connecting the power cable to the battery

Advertising
background image

5

2. WIRING

All wiring are terminated at the rear of the display unit.

ANT

XDR

TEMP/SPD

DGPS

NMEA

+ GND

1 3

2

-

12 - 24

VDC

Display unit

Ground

Earth terminal

Antenna unit

GPA-017
(GP-1850W)

DGPS beacon receiver
(option for GP-1850W,
RS-232C only)

External
equipment

Black

White

Shield

GPA-019
(GP-1850WD)

Display unit, rear view

Power cable

Connect the power cable to the power connector. Connect the leads to the battery (12 or 24
VDC); white to plus(+) terminal and black to minus(-) terminal.

Cable connector

Power cable
w/fuse (5A)

Lead wire

White

Black

BATTERY

Connecting the power cable to the battery

Advertising