2.

Troubleshooting

“SYSTEM ERROR: xx”
occurs.

The following causes are probable, depending
on the symptoms.

1) Turning the power off and back on corrects

the error.


Communication failed because of improper
timing.

1) If communication is stable after turning the

power on again, continue and observe
operation.

2) Turning the power off and back on does not

correct the error.


A certain condition always causes the error.
Or the POD is faulty.

2) Make a note of the information on error

number, etc. displayed on the screen and
contact your local distributor.

3) A CF card is inserted.


The CF card (front and back) may be
reversed.

If none of the above matches your error,
contact your local distributor.

3) Check that the inserted CF card faces the

correct side.

Switches do not work.

1) Switches do not work in the RUN mode. A

beep sounds.


Is the switch interlock enabled?

1) Check the settings of switch functions, etc.

on the editor.

2) Switch activation position is wrong.

On the “I/O Test” screen displayed from the
Main Menu screen, press the [Switch
Check] switch. On the touch switch test
screen, a position different from the
pressed position is activated.


The switch activation position may be
misaligned.

2) Perform a touch switch adjustment (page

6-14).

3) Switches do not work even in the STOP

mode.
On the “I/O Test” screen displayed from the
Main Menu screen, press the [Switch
Check] switch. When the touch switch test
screen is pressed, nowhere is activated.


POD switches may be faulty.

3) Return the POD to your local distributor.

The screen becomes dark or
black.

1) Touching the screen restores it to the

previous illuminated state.


The backlight operates automatically as
preset.

1) The time for turning off the backlight can be

changed on the editor.

2) Touching the screen does not restore it.

However, the POWER lamp is lit.


The backlight may be at the end of its life.
Or the POD may be faulty.

2) Return the POD to your local distributor.

Symptom

Cause

Solution

SYSTEM ERROR : XX

TEA : XXXXXXXX

SSR : XXXXXXXX

R0 : XXXXXXXX

R2 : XXXXXXXX

R4 : XXXXXXXX

R6 : XXXXXXXX

R8 : XXXXXXXX

R10 : XXXXXXXX

R12 : XXXXXXXX

R14 : XXXXXXXX

EXPEVT : XXXXXXXX

SPC : XXXXXXXX

R1 : XXXXXXXX

R3 : XXXXXXXX

R5 : XXXXXXXX

R7 : XXXXXXXX

R9 : XXXXXXXX

R11 : XXXXXXXX

R13 : XXXXXXXX

R15 : XXXXXXXX