DTX-ELT Specifications

Test Standards

• TIA Category 3 and 5e per TIA/EIA-568-B
• TIA Category 5 (1000BASE-T) per TIA TSB-95
• TIA Category 6 per TIA/EIA-568B.2-1
• ISO/IEC 11801 Class C, D, and E
• EN 50173 Class C, D, E
• ANSI TP-PMD
• IEEE 802.3 10BASE-T, 100BASE-TX, 1000BASE-T
• IEEE 802.5 (STP cabling, IBM Type 1, 150Ω ) Token Ring, 4 Mbps and 16 Mbps

Standard Link Interface Adapters

Shielded and Unshielded Twisted

Pair (STP, FTP, SSTP and UTP) data

cabling:

• Channel adapters for: TIA Category 3, 4, 5, 5e and 6: 100Ω
• ISO/IEC Class C and D: 100Ω and 120Ω
• ISO/IEC Class E, 100Ω
• Permanent Link adapter (only with the DTX-ELT PRO): Cat 6/Class E permanent link adapters with
centered Cat 6A test reference plug. This plug is also the test reference for Cat 6 and lower categories.
The life of the plug is rated at 10,000+ insertions. The contact block can be replaced in the field with
the DTX-PLA002PRP replacement parts.

Speed of Autotest

• Full 2-way Autotest of Category 6 Twisted-Pair links in 20 seconds

Supported Tests Parameters

(The selected test standard determines the test parameters and the frequency range of the tests)

Cable Tone Generator

Generates tones that can be detected by a tone probe such as a Fluke Networks IntelliTone probe. The
tones are generated on all pairs. Frequency range of tones: 440 Hz to 831 Hz

Display

3.7 in (9.4 cm) diagonal, 240 dots wide by 320 dots high, passive color, transmissive LCD with backlight.

Input Protection

Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will
not cause damage.

Case

Soft carrying case with shoulder strap

Dimensions

Main unit and Smart Remote: 8.5 in x 4.4 in x 2.4 in (21.6 cm x 11.2 cm x 6cm), nominal

Weight

2.4 lb (1.1 kg), nominal (without adapter or module)

Operating Temperature

0°C to 40°C (32°F to 104°F)

Storage Temperature

-20°C to 60°C (-4°F to

140°F)

Operating relative humidity

(% RH without condensation)

32°F to 95 °F (0°C to 35°C): 0 % to 90%
95°F to 113°F (35°C to 45°C): 0 % to 70 %

Vibration

Random, 2 g, 5 Hz -500 Hz

Shock

1 m drop test with and without module and adapter attached

Safety

CSA C22.2 No. 1010.1: 1992 EN 61010-1 1st Edition Amendments 1, 2

Pollution degree

Pollution Degree 2 as defined in IEC 60664 and applied to IEC 60950 “Safety of Information Technology
Equipment, 1999”

Altitude

Operating: 4000 m; Storage: 12000 m

EMC

EN 61326-1

• Wire Map

• Length

• Propagation Delay

• Delay Skew

• DC Loop Resistance

• Insertion Loss (Attenuation)

• Return Loss (RL), RL @ Remote

• NEXT, NEXT @ Remote

• Attenuation-to-crosstalk Ratio -
Near End (ACR-N), ACR-N @ Remote

• Attenuation-to-Crosstalk Ratio -
Far End (ACR-F) and ACR-F @ Remote

• Power Sum ACR-F (PS ACR-F), PS ACR-F @ Remote

• Power Sum NEXT (PSNEXT), PSNEXT @ Remote

• Power Sum ACR-N (PS ACR-N), PSACR-N @ Remote

Advertising