Grounding – Furuno MU-170C User Manual

Page 13

Advertising
background image

6

Port, cable and connectable equipment

Used cable

Port

Name

Name Type Code

No.

Standard/

Option

Connectable

Equipment

TB-1

Power

cable

14AWG-2C-PVC

*5M*

000-154-337

Standard Power

source

DVI-D

DVI

Cable

DVI-D/D

SINGLELINK5M

000-149-054

Option

PC,

FAR-21X7 series

RGB1

3COX-2P-6C

5M

000-146-500

Option

RGB2

Analog

RGB

Cable

3COX-2P-6C

10M

000-146-501

Option

FCV-1200L/1200LM,

CH-250, CH-270,

CSH-5L/8L,

FSV-24/24S,

GD-280/380/680,

FR-1500 MK3 series,

FR-21X5 series,

NavNet vx2

VIDEO1

VIDEO2

VIDEO3

Prepare the following cable locally.
▪ Connector type: RCA (metal), both ends
▪ Cable length: Max. 10 m
▪ 2.5C2V or 3C2V (Japan Industrial Standard, or the

equivalent) coaxial cable (Impedance: 75 Ω)

Conductor

S = 0.19 mm

= 0.5 mm

2

Shield

Insulator

Vinyl
sheath

Cable 3C2V

Video cassette

recorder, CCD camera,

DVD player

Grounding

Fasten a ground wire (dockyard supply) and the gray crimp-on lug of the power cable to the
ground terminal together. The length of the ground wire should be as short as possible.

Note: Use a “closed-type” lug (

) to make the ground connection. Do not use an

“open-type” lug (

).

Advertising