Specifications – Fluke PN 4060712 User Manual

Page 10

Advertising
background image

62 MAX/62 MAX +
Users Manual

6

Specifications

62 MAX

62 MAX +

Temperature Range

-30

°C to 500 °C

(-22

°F to 932 °F)

-30

°C to 650 °C

(-22

°F to 1202 °F)

Accuracy

≥0 °C: ±1.5 °C or ±1.5 % of
reading, whichever is
greater
(

≥32 °F: ±3 °F or ±1.5 % of

reading, whichever is
greater)
≥ -10 °C to <0 °C: ±2 °C
(

≥14 °F to <32 °F: ±4 °F)

< -10

°C: ±3 °C

(<14

°F: ±6 °F)

≥0 °C: ±1 °C or ±1 % of
reading, whichever is
greater (

≥32 °F: ±2 °F or

±1 % of reading, whichever
is greater)
≥ -10 °C to <0 °C: ±2 °C
(

≥14 °F to <32 °F: ±4 °F)

< -10

°C: ±3 °C

(<14

°F: ±6 °F)

Response Time (95 %)

<500 ms (95 % of reading)

<300 ms (95 % of reading)

Spectral Response

8 to 14 microns

Emissivity

0.10 to 1.00