Split System Heat Pump

4

Specifications subject to change without notice.

LINE SET LENGTH AND SIZE

BTUH

SUCTION LINE SIZES

LIQUID LINE SIZES

15 ft.

25 ft.

50 ft.

75 ft.

15 ft.

25 ft.

50 ft.

75 ft.

18

3/4

3/4

3/4

3/4

3/8

3/8

3/8

3/8

24

3/4

3/4

3/4

3/4

3/8

3/8

3/8

3/8

30

3/4

7/8

7/8

7/8

3/8

3/8

3/8

3/8

36

3/4

7/8

7/8

7/8

3/8

3/8

3/8

3/8

42

7/8

7/8

7/8

7/8

3/8

3/8

3/8

1/2

48

1 1/8

1 1/8

1 1/8

1 1/8

3/8

3/8

3/8

1/2

60

1 1/8

1 1/8

1 1/8

1 1/8

3/8

3/8

3/8

1/2

Recommended liquid & suction tube line size is for standard installations. The unit charge is correct for the outdoor unit, matched indoor coil and
15 feet of refrigerant tubing. For tubing length other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied
by the per foot value. These recommendations do not apply to Long Line Length Installations that exceed 75 feet or where there is more than 40 feet
vertical separation between indoor and outdoor units. (Lengths in excess of 75 feet or more than 40 feet vertical separation are not recommended.)
Note: See unit installation instructions for proper installation.

COOLING PERFORMANCE DATA

OUTDOOR

UNIT

MODEL

AIR

HANDLER

RATINGS AT STANDARD CONDITIONS

COOLING DATA AT EXTENDED OUTDOOR AMBIENTS F.M.B.T.U.H.

BTUH

SEER*

CFM

80

85

90

95

100

105

110

115

CH18ABD1VF

AFPB24A1

18,000

13

650

TOTAL

19,450

18,900

18,450

18,000

17,650

17,200

16,750

16,400

SENSIBLE

15,250

14,950

14,600

14,200

14,050

13,800

13,500

13,250

CH24ACD1VF

AFPB24B1

24,000

13

840

TOTAL

25,800

25,150

24,600

24,000

23,450

22,900

22,350

21,950

SENSIBLE

19,900

19,500

19,050

18,700

18,450

18,000

17,650

17,300

CH30ACD1VF

AFPB36A1

28,000

13

1,000

TOTAL

30,050

29,450

28,750

28,000

27,200

26,550

25,800

25,250

SENSIBLE

23,100

22,600

22,050

21,700

21,450

21,050

20,800

20,550

CH36ACD1VF

AFPB36A1

34,000

13

1,200

TOTAL

36,350

35,500

34,800

34,000

33,250

32,550

31,700

30,950

SENSIBLE

28,300

27,850

27,650

27,250

26,950

26,750

26,350

26,050

CH42ACD1VF

AFPC48A1

40,000

13

1,350

TOTAL

42,700

42,550

40,950

40,000

39,000

38,000

37,400

36,800

SENSIBLE

33,250

32,900

32,100

31,500

30,550

29,600

28,450

27,600

CH48ACD1VF

AFPC48B1

46,000

13

1,550

TOTAL

49,300

48,150

46,950

46,000

44,850

43,650

42,500

41,400

SENSIBLE

40,950

39,750

38,100

36,000

34,800

33,550

32,350

31,150

CH60ACZ1VF

AZFPC60B1

56,000

13

1,750

TOTAL

60,550

59,000

57,450

56,000

54,300

52,450

51,100

49,850

SENSIBLE

44,550

43,950

43,100

42,350

41,700

40,950

40,500

39,600

*TDR required to obtain SEER rating.