6. MAINTENANCE, TROUBLESHOOTING

6-7

6.7 Advanced-level

Troubleshooting

This section describes how to cure hardware and software troubles that should
be carried out by qualified service personnel.

Note 1:
This radar equipment contains complex modules in which fault

diagnosis and repair down to component level are not practicable by
users.

Note 2: When replacement of the SPU board is necessary, the previous settings

can be transferred to new SPU board as follows:
- Use the CU-200 to save settings to a RAM card.
- After replacing the SPU board, load the entire contents of the RAM
card to the radar, referring to section 5.12 for the procedure.

Advanced troubleshooting

Problem

Probable causes or check
points

Remedy

Power turned on but radar
does not operate at all

1) Blown fuse.

2) Mains voltage/polarity

3) Power supply board

1) Replace blown fuse.

2) Correct wiring and input voltage.

3) Replace power supply board.

Brilliance adjusted but no
picture

SPU board

Replace SPU board.

Antenna not rotating

1) Antenna drive

mechanism

2) Defective antenna drive

motor relay (thermal
relay K2, 200/220/380,
440/100 VAC)

1) Replace antenna drive mechanism.


2) Press relay reset button.

Data and marks not
displayed in Transmit
status

SPU board

Replace SPU board.

Adjust GAIN with A/C SEA
set at minimum. Marks and
indications appear but no
noise or echo

1) IF amplifier

2) Signal cable between

antenna and processor
unit


3) Video amplifier board

1) Replace IF amplifier.

2) Check continuity and isolation of

coaxial cable.
Note: Disconnect the plug and lugs
at both ends of coaxial cable before
checking it by ohmmeter.

3) Check video coax line for secure

connection. If connection is good,
replace SPU board.

(Continued on next page)