Fisher & Paykel IZONA RB905 User Manual

Safety and warnings, Product dimensions parts supplied, Cavity preparation

Advertising
background image

Important!

Disconnect power to surrounding appliances before preparing cavity.

Recommended to allow the vertical removal of the refrigerator bins.

WARNING!

Electrical shock hazard

Disconnect product from main power supply before installing appliance.

Failure to do so may result in electrical shock or death

Important safety precautions!

Installation of the CoolDrawer requires competent mechanical and electrical skills.

Be sure to leave these Instructions with the Customer.

Installation must comply with your local building and electricity regulations.

At the completion of the CoolDrawer installation, the Installer must perform the Final Check List.

Remove all packaging materials supplied with the CoolDrawer.

The CoolDrawer is manufactured for indoor use only.

Important!

SAVE THESE INSTRUCTIONS

The models shown in this document may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please go to our website www.

fisherpaykel.com or contact your local Fisher & Paykel dealer.

SAFETY AND WARNINGS

WARNING!

Cut hazard

Take care - panel edges are sharp.

Failure to use caution could result in injury or cuts.

1

2

The CoolDrawer MUST be installed to allow for future removal from the enclosure if service is required.

Do not seal the CoolDrawer into the cabinetry with silicone or glue. Doing so will make future servicing
difficult. Fisher & Paykel will not be liable for any costs associated with removing or replacing a sealed-in
product, nor for repairing any damage that may be incurred by doing this.

Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to the

power supply cord.

Failure to install the CoolDrawer correctly will invalidate any warranty or liability claims.

If the power supply cord is damaged, it must be replaced. Parts are available from your Authorised Fisher

& Paykel dealer.

This appliance is not intended for use by persons (including children) with reduced physical, sensory or

mental capacities, or lack of experience and knowledge unless they are supervised or given instruction
concerning use of the appliance.

Cabinetry must be sufficiently robust to support a combined product and food load of 100 kg. Bearers may

be required to support the internal shelf.

Before you install the CoolDrawer, please ensure that

The switched power outlet must be outside the refrigerator drawer cavity so that it is accessible after

installation.

The switched power outlet must be located outside the cavity, within 1400 mm from the CoolDrawer

cavity if situated on the left-hand side of the cavity and within 850 mm if situated on the right-hand side
of the cavity.

The services hole in the refrigerator cavity needs to be large enough for the power supply plug to fit

through.

PRODUCT DIMENSIONS

PARTS SUPPLIED

4

5

CAVITY PREPARATION

IZONA CoolDrawer

Installation instructions

RB90S & RB36S models

FRAMELESS CABINETRY

WARNING!

Tipping hazard

Do not operate this apppliance until it has been securely anchored inside the

cabinetry. The cabinet must be securely anchored to the floor.

Failure to use caution could result in injury or cuts.

Product dimensions

(mm)

C

oolDr

aw

er

RB90S

RB36S

A

overall height of product

(inc. installation brackets)

640

B

overall width of product

855

C

overall depth of product

(excl. drawer panel; inc. power cord)

557

D

depth of drawer

(open)

(excl. handle)

520

Installation diagrams for illustration purposes only

A

D

H

Cabinetry dimensions

(mm)

C

oolDr

aw

er

RB90S

RB36S

A

overall width of cabinetry frame

900

B

minimum inside width of cabinetry frame

864

C

internal height of cabinetry to top of spacer block

644

D

internal height of cabinetry*

(to allow for product and outlet duct height)

min. 665

max. 764

E

minimum height of toe kick

75

F

minimum depth** of toe kick

40

G

minimum distance from front of cabinetry to rear wall

560

H

width of spacer blocks

50

*Minimum internal height of cabinetry can be 644 mm if outlet duct is not used.

**All depth measurements are taken from the front face of the cabinetry frame (not drawer panel)

Minimum clearances

(mm)

2 mm

13 mm

E

B

C

D

G

F

F

C

G

Installation

trims (2)

Installation brackets

(left-hand and right-

hand side) (2)

Outlet duct (1)

Trim brackets (4)

Drawer Panel

attachment

hooks (3)

Power

cord (1)

Note: Ser

vices can

be located

either side

of CoolDr

awer.

max.

20 mm

max. 850 mm

min. ø50 mm

Benchtop

Pa

ne

l

min. 535 mm

Installation diagrams for illustration purposes only

Draw

er Panel

16-20

mm

False

Panel

(896

mm

)

height of False Panel

4 mm

6

INTEGRATED PANEL PREPARATION

A

B

130 mm min.

Phillips 16 mm

wood screw (6)

Pan Head

16 mm

screw (12)

Pan Head

16 mm

screw (2)

Phillips

16 mm

wood

screws (6)

min. 535mm

min. 130mm

height of

Drawer

Panel

3

CABINETRY DIMENSIONS

Shows cutout if cabinetry
depth at minimum 550 mm

Benchtop

D

ra

w

er

p

an

el

Fa

ls

e

p

an

el

A

D

E

C

B

Integrated Panel material

16 - 20 mm panel thickness (18 mm recommended).

Maximum weight of 7 kg.

Adequately sealed to withstand moisture (50

O

C @ 80% RH)

Height of Drawer Panel

The following information is required to correctly define your drawer panel height:

Dimension

Data Source

A Clearance between top of Drawer panel and underside

Your kitchen designer

of benchtop

B Height between underside of cabinetry ceiling

Your kitchen designer

and underside of benchtop

C Internal height of cabinetry to top of spacer block

644 mm

D Drawer panel height

Calculated from A, B, C & E

E Bottom face of Drawer panel to top of spacer block

Your kitchen designer

(to ensure that bottom cover of product is not exposed)

(Min. 154 mm, Max. 184 mm)

To calculate D complete the following equation:

D = C + B - A - E

i.e. For the F&P prefinished panel:
476 mm = 644 mm + 18 mm - 2 mm - 184 mm

Height of the False Panel

Determine the height of the false panel according to your individual kitchen cabinetry

requirements maintaining a 4 mm gap between panels.

F&P prefinish panel width is 896 mm assuming a 2 mm clearance either side of panel

height (D) is 476 mm.

Note B must be min. 16 mm to ensure adequate clearance to benchtop.

An internal shelf can be used as an alternative to spacer blocks to

position the product at the correct height. In this case additional

cutouts will be required. Refer to Step 7.

SIDE VIEW

Advertising