FUJITSU 50FH5037E-02 User Manual

Page 60

Advertising
background image

(c)

Control register #2

X©00π is set when the power is turned on or when a CLEAR command is issued for
initialization.

7

6

5

4

3

2

1

0

0

LSB

MSB

Jam detection when scanning

0 : Executed
1 : Not executed

Specifies halftone

0¥ :

Set from the operator panel

1 0 :

Not dithered

1 1 :

Dithered or Error Diffusion (*2)

Dither pattern (*1)

0 0 0
0 0 1
0 1 0
0 1 1
1 0 0
1 0 1
1 1 0
1 1 1

Built>in/Download

0 : Built>in
1 : Download

*1

f

When the built>in pattern is used, the density information shown in the
control register #1 is valid.

f

4 patterns (000 to 011) are valid when the built>in pattern is selected.

f

When the download pattern is used, the density information shown in
Control register #1 is invalid.

f

8 patterns (000 to 111) is valid when the download pattern is selected.

*2 Dithered or Error diffusion are selected by control register #19.

6 $ 10

50FH5037E>02

Advertising
This manual is related to the following products: