1.3 Troubleshooting Procedure

Maintenance and Diagnosis

1-12

C141-F059-01EN

Table 1.3 System level and field troubleshooting

Check to be made

Recommended work

DC power voltage
level

Confirm that the DC power voltage is within

±

5% of the standard value.

When measured at pins 41 and 42 of the power supply connector, the +5
VDC must be 4.75 to 5.25 VDC.

DC power ripple
noise

Check that the maximum ripple at +5 VDC power is less than 100 mV
peak to peak and 200 mV peak to peak respectively.

Power-interface
cable connection

Confirm that the AT interface cable is properly connected at the disk
drive, power supply section, and control unit.

Switch setting

Confirm that the switch on the disk drive control PCA is set for normal
operation with the host computer. Refer to Section 3.4 of the
MHS2060AT, MHS2040AT, MHS2030AT, MHS2020AT Disk Drives
Product Manual
for switch setting.

System cable

Confirm that all cable connections throughout the system correctly
connected.

System diagnostic
test

To further isolate the failure, if it can be done, execute the system level
diagnostic routine described in the host computer manual.

Intermittent or
indefinite error

Check the AC voltage level at the power supply section and recheck the
DC voltage level at the disk drive power supply connector.

If the AC voltage level is abnormal, or if there is a lot of electrical noise,
notify the user.

If the DC voltage level is unstable, replace the power supply section.

If possible, replace the disk drive. If the fault remains, the disk drive is
not the case. For suggestions to isolate the failure further, refer to the
hardware and software manuals provided with the system.