10 adjustments after installation – Furuno FCV-620 User Manual

Page 47

Advertising
background image

4. INSTALLATION

38

4.10 Adjustments after

Installation

NMEA

1. Press the MENU/ESC key to open the

menu.

2.

Use

S

or

T

to choose NMEA under System

menu and press the ENTER key.

NMEA menu

NMEA0183

Choose NMEA0183 version of nav equipment
connected to “12-24 VDC/NMEA” port among
Ver 1.5, Ver 2.0 or Ver 3.0.

NMEA Port

The NMEA terminals in the “12-24 VDC/
NMEA” port can function as input ports or
input/output port. Change the setting to "In/In"
when connecting GP-310B/320B and a wind
sensor.

When connecting the GP-320B and a wind
sensor, first turn on "WAAS Setup" and then
select "In/In" as the NMEA Port setting.

In/Out: Input and Output (default setting)
In/In: Input only (Available with connection of
the GP-310B/320B and a wind sensor.)

NMEA Output

Set the output data sentences (see the left-
table).

Off: Outputs the “output data sentences” of
FCV-620/585 only.
On: Outputs the “output data sentences” of
FCV-620/585 and sentences which are input
from other equipment.

WAAS Setup

Choose how to use the WAAS signal when
connecting with a WAAS receiver, for
example GP-320B. The message types
(WAAS-00 to WAAS-27) are used as WAAS
correction. Choose WAAS-00 to enable
WAAS.

Note: This function is available only when In/
Out is selected at NMEA Port.

TLL Output

Output the position specified by MARK key to
the plotter connected.

Off: Does not output latitude/longitude.
TLL: Outputs latitude/longitude.
FURUNO-TLL: Outputs latitude/longitude,
depth and water temperature. Required
FURUNO-TLL enabled device.

Port Monitor

Port Monitor provides information for the data
sentences input to the 12-24 VDC/NMEA
port.

Press the ENTER key to display the latest
data sentence information. To display this
information on the Port 2 screen when two
sensors are connected, set NMEA Port on the
NMEA menu to In/In.

Transducer (FCV-585 only)

Choose transducer type among 600 W, 1 kW
and 50/200-1T on the Sounder menu.

Transducer setting box

600 W: For 600 W transducer
50/200-1T: For 1 kW transducer (50B-6, 50B-
6B, 200B-5S or 50/200-1T)
1 kW: For 1 kW transducer other than those
mentioned above

NMEA

S

/

T

/

W

/

X

: Select

[ENTER] : Enter
[MENU] : Back

NMEA0183 : Ver 2.0
NMEA Port : In/Out
NMEA Output : Off
WAAS Setup : Off
TLL Output : TLL
Port Monitor

Port Monitor

$GPGLL, 4928. 186, N, 00022. 705, E, 00035
2, A*24<0d><0a>
$GPVTG, , , 2.6, M, 1.0, N, 1.9, K*39<0d><0
a>
$GPRMC, 000352, A, 4928.186, N, 00022.70
5, E, 001.0, 000.0, 301006, 2.6, W*6B<0d>
<0a>

Port 1

600W
1kW
50/200-1T