5.4.2 Filter Operation (cont.)

4. After ensuring the filter pan is correctly

positioned under the drain tube, and the pan-
disconnect is properly connected, pull the red
handle to drain the frypot into the filter pan.

5. After all oil/shortening has drained from the

frypot into the filter pan, pull the yellow
handle to open the oil return line and activate
the filter pump.

Pull the red handle to open the drain valve.

Pull the yellow handle to open the oil return valve
and activate the filter pump.