Frymaster Dean 2424E User Manual

Page 12

Advertising
background image

2-5

fryers without the built-in boil out option, the power switch is on the front panel. For those with
the option, the switches are located inside the door.

If this light does not remain
lit when switch is released,
the drain valve is open.

When this switch is in the
POWER position, this indicator
will be lit whenever the heating
elements are engergized.

NOTE: The Fryer Reset switch and
Boil Out switch are not present in all
configurations.

3. The light in the POWER switch should illuminate, indicating that the elements have been

energized (see illustration above). It will remain lit until the fryer reaches the temperature set on
the thermostat or controller.


4. When the water in the frypot begins to boil, reset the thermostat to 200°F (95°C) or less to verify

that the elements and thermostat or controller are functioning correctly. The elements should
turn off and the water should stop boiling.

If the elements DO NOT turn off, press the POWER switch to the OFF position. If you are not
a Frymaster/Dean certified technician, call your local FASC for service. DO NOT attempt to
operate the fryer until the problem has been corrected!

If you are a certified technician, refer to the troubleshooting guides in Chapter 5 of this manual.


5.

FOR UNITS EQUIPPED WITH THE OPTIONAL BOILOUT SWITCH:

Press the switch to the

BOIL OUT position (see illustration on Page 2-4). This feature will maintain the frypot
temperature at 195°F (90°C) until the switch is placed in the OFF position. Simmer the solution
for approximately 1 hour. Do not allow the water level to drop below the bottom OIL LEVEL
line in the frypot during the boilout operation.

FOR UNITS WITHOUT THE OPTIONAL BOILOUT SWITCH:

Reset the operating thermostat to

195° (90°C). Simmer the solution for approximately 1 hour. Do not allow the water level to drop
below the bottom OIL LEVEL line in the frypot during the boilout operation.

DANGER

Do not leave the fryer unattended during the boilout process. The boilout solution
may foam and overflow. Press the POWER switch to the "OFF" position to control

this condition.

Advertising