Clogged pilot orifice, Loose/corroded wire connections, Low or no voltage out of thermopile – Frymaster 35 Series User Manual

Page 16

Advertising
background image

1-12

6. Basket Lift malfunctions.
The probable causes of each category are discussed in the following sections. A series of
Troubleshooting Guides is included at the end of the chapter to assist in identifying some of the
more common problems.

1.9.1 Pilot Failures

There are two categories: no pilot flame and unreliable flame.

No pilot flame

1. No gas or insufficient gas supply

2. Clogged pilot orifice

3. Air in gas lines ( usually in new installations)

Unreliable flame

1. Open or grounded high limit

2. Loose/corroded wire connections

3. Low or no voltage out of thermopile

4. Bad gas valve

1.9.2 Problems Related to the Gas and/or Electrical Current

CONTROL CIRCUIT FOR THE 35 SERIES MILLIVOLT IGNITION SYSTEM