Frymaster Enodis MPH52/55 SERIES User Manual

Page 25

Advertising
background image

1-18


2. Remove the filter pan from the unit and drain one frypot at a time into a Shortening Disposal

Unit (SDU) or other appropriate metal container.

DANGER

DO NOT attempt to drain more than one full frypot or two split frypots into the SDU

at one time.


3. Dismount the topcap by removing the screws on the bottom of each front corner and lifting the

topcap straight up.


4. Remove the bezels by lifting them up to disengage the tabs along the lower edges from the slots

in the control panel frame. Remove the top two screws in the upper corners of the control panel.


5. Grasp the upper edge of each controller and swing the controller downward. Unplug the

controller wiring harness and grounding wire from the back of each controller.


6. Remove the controllers by lifting them from the hinge slots in the control panel frame.

7. Remove the clevis that secures the oil return rod to the oil return handle and separate the rod and

handle. NOTE: On split-vat units, there are two oil return handles.


8. Disconnect the sound device wire from the interface board and disconnect the oil return switch

wires from the switch terminals.


9. Disconnect the flame sensor wires by carefully pulling the push-on terminals from the terminal

strips on the ignitors. Disconnect the gas enrichment tube at the ignitor-end compression fitting.
Disconnect the ignition cables from the ignitors by grasping the boots and gently pulling toward
you.


10. Remove the two mounting screws on each side of the component box and rotate the top of the

box out of the frame. Carefully pull it out enough to disconnect the wiring harness connector
from the back of the box. Cut any ties that prevent the box from being pulled out of the control
panel frame.


11. Carefully pull the box clear of the frame and rest it atop the fryer.

12. Using a pin pusher, remove the temperature probe and high-limit thermostat wires from the plugs

or terminals, marking each wire to facilitate re-assembly.


13. Remove the cover from the safety drain switch. Disconnect the wires from the switch.

14. Remove the section(s) of drain from the drain valve(s) of the frypot to be removed.

15. Disconnect the gas lines from the burner orifices and ignitor assemblies.

16. Remove the frypot hold down bracket.

Advertising