Volt min, Volt max – Fortinet 2 SXRC User Manual

Page 51

Advertising
background image

51

SXRC Remote Control

Opera

tion

VOLT MIN

MENU - Here you can view the lowest voltage

seen at each amplifier’s +12 volt terminal since being installed.

Once you select the

VOLT MIN

menu, a

list of all the amplifiers connected to the
SXRC will be displayed in a scrolling list.

Use the

UP

or

DOWN

keys to scroll

through the list of available amplifiers.

When you have the amplifier selected you
wish to view simply press the

ENT

key to

select it.

The selected amplifier’s minimum +12
volt terminal reading will be displayed.

When done viewing the current amplifier’s
minimum voltage, press the

ESC

key to

return to the list of available amplifiers.

You can now select another amplifier by using
the

UP

or

DOWN

keys and view its

minimum voltage by pressing the

ENT

key

OR

Press the

ESC

key to return to the SICK

BAY menu and select another function.

s x

x -

- 5

5 0

0 0

0 /

/ 2

2

SYS

MEM-1

GAIN EQ LPF HPF

KOMP

AMP1

LOCK

MEM-2

MEM-3

MEM-4

PHASE

MUTE

AMP2

LEFT

RIGHT

HOME

ENT

ESC

HOME

ENT

ESC

1

1

0 5

5

v

v o

o l

l t

t s

s

SYS

MEM-1

GAIN EQ LPF HPF

KOMP

AMP1

LOCK

MEM-2

MEM-3

MEM-4

PHASE

MUTE

AMP2

LEFT

RIGHT

HOME

ENT

ESC

HOME

ENT

ESC

HOME

ENT

ESC

VOLT MAX

MENU - Here you can view the highest voltage

seen at each amplifier’s +12 volt terminal since being installed.

Once you select the

VOLT MAX

menu, a

list of all the amplifiers connected to the
SXRC will be displayed in a scrolling list.

Use the

UP

or

DOWN

keys to scroll

through the list of available amplifiers.

When you have the amplifier selected you
wish to view simply press the

ENT

key to

select it.

The selected amplifier’s maximum +12
volt terminal reading will be displayed.

When done viewing the current amplifier’s
maximum voltage, press the

ESC

key to

return to the list of available amplifiers.

You can now select another amplifier by using
the

UP

or

DOWN

keys and view its

maximum voltage by pressing the

ENT

key

OR

Press the

ESC

key to return to the SICK

BAY menu and select another function.

s x

x -

- 5

5 0

0 0

0 /

/ 2

2

SYS

MEM-1

GAIN EQ LPF HPF

KOMP

AMP1

LOCK

MEM-2

MEM-3

MEM-4

PHASE

MUTE

AMP2

LEFT

RIGHT

HOME

ENT

ESC

HOME

ENT

ESC

1

1

4 8

8

v

v o

o l

l t

t s

s

SYS

MEM-1

GAIN EQ LPF HPF

KOMP

AMP1

LOCK

MEM-2

MEM-3

MEM-4

PHASE

MUTE

AMP2

LEFT

RIGHT

HOME

ENT

ESC

HOME

ENT

ESC

HOME

ENT

ESC

Advertising