8. PLOTTER ALARMS

8-4

8.8 Alarm

Information

When an alarm setting has been violated the
buzzer sounds and the speaker icon (shown
in red) appears. You can see which alarm
has been violated, as well as silence the
buzzer, on the alarm menu display.

1. Press the [ALARM] key.

DGPS 3D

ALARM

EDIT

CLEAR
ALARM

ALARM INFORMATION

AUDIO ALARM
ARRIVAL ALARM
ANCHOR ALARM
PROXMTY ALARM
XTE ALARM
SPEED ALARM

ON
ON 0.100nm
ON 0.050nm
ON
ON 0.100nm
OVER/UNDER
12.5 ~ 15.0kt

YOU HAVE ARRIVED AT

WAYPOINT : SP-001.

Alarm information
(Example: Arrival alarm)

Alarm menu


2. Press the CLEAR ALARM soft key to

silence the buzzer. The color of the alarm
message and the speaker icon changes
from red to black.


Note:

The speaker icon is displayed in red

until all alarms have been
acknowledged on the alarm menu
display. If more than one alarm has
been violated the message
CONTINUE appears at the bottom of
the display. In this case press the
NEXT INFO soft key to see which
other alarms have been violated.

Alarm messages

Alarm messages and their meanings

Message Meaning

YOU HAVE ARRIVED
AT WAYPOINT.

Arrival alarm setting
violated.

YOU HAVE EXCEEDED
ANCHOR WATCH

LIMIT.

Anchor watch alarm
setting violated.

YOU HAVE ENTERED
AN AVOIDANCE AREA.

Proximity alarm
setting violated.

YOU HAVE EXCEEDED

XTE LIMIT.

XTE alarm setting

violated.

YOU HAVE EXCEEDED
SPEED ALARM LIMIT.

Speed alarm setting
violated.