11. Place the new temperature probe assembly

onto the element and secure with the screws
removed earlier. Clip the probe onto the rear
of the element. The temperature probe
assembly should be oriented in the same
manner as the probe being replaced.


12. Thread the probe wires into the harness

connector as removed in Step 7.


13. Lower the element into the frypot.









14. Place the tilt housing cover over the tilt

housing assembly and secure with screws


15. Install the top, center and bottom back covers

and secure with screws.




























Secure probe to
element with metal
wire-wrap

New probe assembly
properly installed in
tilt plate