F3000 TEST PROCEDURE FOR LEGACY FRYMASTER FRYERS
(KJ3, 118G, H55, MJ45, 118E/RE80 and FPRE114/117)

Ensure the controller is set to LEGACY-FRYMASTER using code 7628 in tech mode.
With the Controller displaying OFF press and hold the check button until PRODUCT
SETUP is displayed. Press the right arrow to tech mode. Enter 7628. Set LOCALE to
NON-CE. Press the right arrow. Set system type to LEGACY-FRYMASTER. Press the
right arrow. Set ENERGY to ELEC or GAS. Press the right arrow. Set TYPE to fryer type
desired. Press the right arrow. Set FRESH OIL to NONE. Press the right arrow. Set
WASTE OIL to NONE. Press the right arrow. Press the check button at EXIT.

A.

INITIAL TEST SET-UP

1.

Set-up FTB-350A as follows:
(a) Set POWER switch (10) to OFF.
(b) Set PROBE switches (6 & 7) to Variable.
(c) Connect 120/24V transformer to 120VAC outlet or 240/24V

transformer to 240VAC outlet.

2.

Set controller up as follows:
(a) Set POWER switch to OFF.
(b) Connect FTB-350A 16-pin connector to rear of controller.

3.

Set FTB-350A POWER switch (10) to ON
(a) Program the controller set point to 340°F/171°C.

B.

TEST POWER TO FRYER INTERFACE BOARD

1.

Press controller ON/OFF switch to ON.

2.

RELAY POWER indicator (3) should illuminate.

3.

Turn power off by pressing and holding the ON/OFF switch on the
controller for approximately three seconds.

NOTE: If testing a split vat controller or dual vat controller, complete previous
step utilizing both controller power switches (one ON at a time. Both sides of
these controllers can be tested at the same time.).

C.

TEST MELT-CYCLE FUNCTION

1.

Press controller ON/OFF switch to ON.

2.

Set FTB-350A PROBE switches (6 & 7) to 3°C/37°F.
(a)

RELAY POWER indicator (3) illuminates.

(b)

HEAT indicators (2 & 4) should cycle on and off. “MLT-CYCL” is
displayed on the controllers alternating with setpoint on the left and
actual temperature on the right.

3.

Set FTB-350A PROBE switches (6 & 7) to 97°C/206°F.
(a) HEAT indicators (2 & 4) should illuminate continuously.
(b) Setpoint is displayed on the left and actual temperature on the right.

NOTE: On a full vat controller, only RIGHT HEAT indicator (4) will

function and only VARIABLE knob (9) will function.

4. Turn power off by pressing and holding the ON/OFF switch on the

controller.