1-6

Direct frequency entry

Rx frequency may can be entered manually. (Tx frequency may also be entered where permit-
ted.)

Rx frequency

To set for a receive frequency of 1636.4 kHz, for example;

Press [RX], [1], [6], [3], [6], [4], [ENT] in this order. Entry of the decimal point is not required.

Tx frequency

To set for a transmit frequency of 2061.4 kHz, for example;

Press [TX], [2], [0], [6], [1], [4], [ENT].

R

0 2 4 6 8 10 S

SQ

J3E

AGC NB

DUP

RX freq
(Tx freq
shown at Tx)

Figure 1-4 Sample frequency display

• The [CURS/2] key shifts the cursor among last 4 places (J3E) or two places to left of decimal

and one place to right of decimal (H3E).

• To modify a value at a particular digit (Rx frequency only), use the [FREQ/CH]

control; it changes the value above the cursor.

Paired Rx/Tx frequency

To set for 2161 kHz simplex channel, for instance, press as below;

[TX]*, [RX]*, [2], [1], [6], [1], [0], [ENT]

Do not forget to enter the last zero in the above example. The last numeral represents the 1/10
decimal place. Simply hitting [TX], [RX], [2], [1], [6], [1], [ENT] will set 216.1 kHz.

* Order of pressing may be reversed, that is, you may press [RX] first.