Pro te cto r g as fr ye rs, Frymaster – Frymaster FPGL330 User Manual

Page 2

Advertising
background image

Frymaster

®

Pro

te

cto

r G

as

Fr

ye

rs

M

o

d

el

#_

__

__

__

__

__

__

__

C

SI

Se

ct

io

n

1

14

00

8700 Line Avenue 71106

P. O. Box 51000 71135-1000

Shreveport, LA USA

Tel: 318-865-1711

Tel: 1-800-221-4583

Fax: 318-868-5987

E-mail: [email protected]

www.frymaster.com

Bulletin No. 818-0583 4/08

Litho in U.S.A. ©Frymaster, LLC

diMenSiOnS

17.19 [437]

CORDSET

LOCATION

6.48 [165]

CORDSET

LOCATION

45.60

[1158]

8.50

[216]

11.83

[300]

36.50

[927]

46.86

[1190]

LEFT SIDE VIEW

FRONT VIEW

RIGHT SIDE VIEW

BACK VIEW

TOP VIEW

1" NPT GAS SUPPLY

DRAIN

HEIGHT

29.64

[753]

21.75

[552]

18.72

[475]

51.48

[1308]

FILTER PAN

PULLED OUT

We reserve the right to change specifications appearing in this bulletin without incurring any obligation for equipment previously or subsequently sold.

moDel no.

oIl

CAPACIty

overAll SIze (mm)

net

weIght

ShIPPIng InformAtIon

heIght

wIDth

length

weIght ClASS Cu. ft.

DImenSIonS (mm)

FPGL230

30 lbs.

(15 liters)

per frypot

45.60”*

(1158)

31.24”

(794)

29.64”

(753)

500

(227 kg)

544

(247 kg)

77.5

52.84

H

54”

(1372)

W

38”

(965)

L

44.50

(1130)

FPGL330

46.86”

(1190)

675

(306 kg)

723

(328 kg)

74.39

53.30”

(1359)

FPGL430

62.48”

(1587)

858

(390 kg)

908

(412 kg)

100.12

72

(1829)

*without basket lifts

nOTeS

Supply Voltage 120V 60Hz
120 VAC 5 ft. (1.5 m) grounded cord set provided.
Recommended minimum store supply pressure
to be 6” W.C. for NAT Gas, and 11” W.C. for L.P.
Check plumbing codes for proper supply line siz-
ing to attain burner manifold pressure of 3.0” W.C.
natural or 8.25” W.C. L.P. Incoming supply line
should be 1-1/2”. Should flexible gas line be used,
it must be AGA approved, commercial type and
sized per the gas line size in above drawing.

CLeARAnCe inFORMATiOn

A minimum of 24” (610 mm) should be provided

at the front of the unit for servicing and proper

operation, and 6” (152 mm) between the sides

and rear of the fryer to any combustible material.

POweR RequiReMenTS

POweR RequiReMenTS FOR FiLTeR OnLY

AMPERAGE FOR FILTER ONLY -- Filter Motor -- Domestic: 120V 60 Hz (7.5 AMP)
Export: 220V-240V 50/60 Hz (4.5 AMP) -- Contact factory for other voltages

moDel

no.

nAturAl or lP

gAS InPut rAtIng

eleCtrICAl

exPort

FPGL

75,000 Btu/hr. input

(18,892 kCal)

(21.97 kW)

Non-basket lift

120V (1.0 AMP)
220V (0.5 AMP)

Basket Lift

120V (7.0 AMP)
220V (3.5 AMP)

200V - 250V

50/60 Hz.

3.5 AMP

Advertising