Resetting Image File Name Sequence Number

6

6-9

Resetting Image File Name Sequence Number

To change the file sequence number used in the saved image name:

Note

If a file sequence number you want to use for image B is already used
for image A, the camera automatically selects the lowest possible
sequence number for image B and does not override, or delete,
image A.

1. Tap F.

2. Use the MOUSE controller to position the pointer over Camera Settings

on the popup menu.

3. Tap E.

4. Position the pointer over the Files tab and tap E.

5. Position the pointer over Reset and tap E to reset the sequence numbers

back to 0000.

6. Tap the TRIGGER button to accept setting change and return to scan

target mode.

Selecting Video Output Options

Using the video port and video cable, you can display the live, paused, or
saved images on a TV, video projector, or video monitor. You can also record
images on a video recorder.

Video output can be set to NTSC, PAL, or disabled.

Note

Disable the video output function when not in use to save
battery power.

To select NTSC or PAL signal and enable/disable video output:

1. Plug the video cable (the end with the cylindrical noise suppressor) into

the camera video port; plug the other end of the cable into the TV,
projector, monitor, or video recorder.