Cabinet Service Procedures

2-6

2.3 Accessing the Electronic Components
1. The component shelf is accessed by removing two screws on each side of the unit (Fig. 1).
2. Lift and remove the sides, which exposes screws that hold the top in place (Fig. 2).
3. The components are annotated below (Fig. 3).



































All the components are readily removed. There are no replaceable components on the circuit boards.

2.4 Circuit Board LED Diagnostics

Master Control Board:

HB LED is a heartbeat; should

be flashing when in the normal
in- use mode. Flash rate is not
critical.

ACT LED similar to HB but

flashes at a faster rate.

OK LED toggles each time a valid communication packet is sent and received. Normally a

very fast flicker.

Relay

Fans: are specific to
regions of the cabinet
and ducted to direct
the air flow.

Fig. 4: Master Control Board LED's 

Figure 3

Master
Display
Board

LON
filter

Master Control
Board

LON board

LON
filter

Power
supply

Cooling
fans

NOTE: The cooling fans 
rest on ducts, and cool 
specific regions of the 
cabinet.