Troubleshooting, Warning – Graco Inc. 965786 User Manual

Page 10

Advertising
background image

10

308876

Troubleshooting

WARNING

To reduce the risk of serious injury
whenever you are instructed to relieve
pressure, always follow the Pressure

Relief Procedure on page 8.

SKIN INJECTION HAZARD

1.

Relieve the pressure.

2.

Check all possible causes to the problem before
disassembling the pump.

PROBLEM

CAUSE

SOLUTION

Valve does not open

Insufficient air pressure

Turn on or turn up air pressure.

Air not exhausted from behind air cylin-
der piston

Use four-way, relieving-type air valve operator.

Shaft adjustment too far closed

Adjust the shaft stroke as instructed on page 9.

Valve does not close
(leaks)

Insufficient air pressure

Turn on or turn up air pressure.

Air not exhausted from behind air cylin-
der piston

Use four-way, relieving-type air valve operator.

Blockage between needle and seat

Remove and clean needle and seat.

Bad or missing gasket between seat
and housing

Replace gasket (38).

Needle worn out

Replace needle and seat.

Higher than normal
back-pressure

Nosepiece plugging up

Remove and clean.