2 installation, 10 electrical installation, 11 immersion heater – Glowworm Lighting 250 I User Manual

Page 16: 12 thermostat setting, 13 thermostat and sensor wiring, Diagram .7, Diagram .9, Diagram .8

Advertising
background image

6

2 Installation

2.10 Electrical installation

Remove the front fascia panel.
Wiring should be performed by a

competent person in

accordance with the building regulations, Part P of the

current IEE regulations and further applicable regulations and

directives.
The discharge pipes of the tundish, drain valves, motorised

valves etc. should be laid at a safe distance to electrical

components.
IMPORTANT: Danger of death from electric shock! You must

earth the solar cylinder for potential equalisation.

2.11 Immersion heater

The Flurocyl solar cylinders incorporate an immersion heater.
IMPORTANT: Danger of death from electric shock! You must

earth the immersion heater for potential equalisation.
Install a separate electrical power supply line for the

immersion heater in accordance with current IEE regulations

(BS 767).
You must lay a heat-resistant line (3 x .5 mm



) from a double

pole isolating switch for the immersion heater. The circuit must

be protected by a 3 A fuse.
The connection of the immersion heater is illustrated in detail

in diagram .7.
IMPORTANT: Risk of damage! The immersion heater

is equipped with a thermal cut out and may under no

circumstance be replaced by a standard immersion heater.
Only correct original Glow-worm spare parts are permitted.

2.12 Thermostat setting

The entire inner wiring has been pre-assembled at the factory.
IMPORTANT: Risk of damage! Switch off the power supply

before resetting the thermal cut out or making any other

changes to the temperature setting of the cylinder thermostat.
The cylinder thermostats for the regulation of the hot water

temperature are factory set at 65°C as the Domestic Hot

Water temperature is controlled by the adjustable thermostatic

mixing valve.Ensure both control thermostats are adjusted

fully clockwise.
Actuate the reset buttons, to reset the thermal cut outs if

necessary, see diagram .7.
IMPORTANT: Risk of damage! If the immersion heater is not

connected, you must connect the earth wire to terminal E

on the terminal strip of the immersion heater. You can find a

wiring sheme on the inside of the cylinder cover.

2.13 Thermostat and sensor wiring

Connect the domestic hot water demand wiring to the reheat

control thermostat as shown in diagram .8 and .0.
Connect the solar pump live via the solar thermal cut out and

ensure this thermal cut out is earthed, as shown in diagram

.8. and .0.
Install the two temperature sensors in the solar cylinder, see

diagram .9, and connect to the solar control, see diagram

.0.
Attach the solar gain sensor to the solar circuit return, see

diagram .9.
Replace the front fascia panel.

IMMERSION HEATER

THERMAL CUT OUT

WITH RESET BUTTON

REHEAT

THERMAL

CUT OUT WITH

RESET BUTTON

REHEAT

THERMOSTAT

(FACTORY SET)

IMMERSION HEATER

THERMOSTAT

(FACTORY SET)

IMMERSION

HEATER

CONNECTION

230V AC 3 kW

TEMPERATURE SENSORS

IN IMMERSION SLEEVES

230V

AC

3 kW

30°

40

°5

65°

30°

40

°5

65°

L

N

1

2

3

Diagram .7

4

90

4

9



Diagram .9

4

94

UPPER

TEMPERATURE

SENSOR

LOWER

TEMPERATURE

SENSOR

TEMPERATURE

SENSOR

GAIN

30

°40

°

50°

65°

30

°40°

50°

65°

L
N

1

2

3

DOMESTIC

HOT WATER

DEMAND

WIRING

REHEAT

CONTROL

THERMOSTAT

(FACTORY SET)

SOLAR THERMAL

CUT-OUT WITH

RESET BUTTON

Diagram .8

Advertising