Wiring diagrams – Goodman Mfg GMH95 User Manual

Page 14

Advertising
background image

14

WIRING DIAGRAMS

Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.

GMH95[0453,0704,0905]*XAB

GMH95[0703,0904,1155]*XAC

HIGH VOL

T

A

G

E

!

DIS

C

ONNECT

AL

L

POW

E

R BEF

O

RE

SERVICI

NG OR IN

S

T

A

L

L

IN

G

T

H

IS

UNIT

.

M

U

L

T

IPL

E

PO

W

E

R SO

UR

CES M

A

Y BE P

R

ESEN

T

.

F

A

IL

URE

T

O

DO

SO

M

A

Y CAUS

E

PRO

P

ERTY DAM

A

G

E

,

PERSO

NAL

I

N

J

U

R

Y

O

R

DE

A

T

H

.

R

YL

YELLOW

OR

ORANGE

PU

PURPLE

GN

GREEN

BK

BLACK

BR

BROWN

WH

WHITE

BL

BLUE

GY

GRAY

RD

RED

COLOR

CODES:

LOW

VOLTAGE

(24V)

LOW

VOLTAGE

FIELD

HI

VOLTAGE

(115V)

HI

VOLTAGE

FIELD

NOTES:

1.

SET

HEAT

ANTICIPATOR

ON

ROOM

THERMOSTAT

AT

0.7

AMPS.

2.

MANUFACTURER'S

SPECIFIED

REPLACEMENT

PARTS

MUST

BE

USED

WHEN

SERVICING.

0140F00592

REV.

A

OR

(MED

LOW)

BL

(MED)

RD

(LOW)

GAS

VALVE

C

PM

C

G

W

INTERNAL

TO

INTEGRATED

CONTROL

JUNCTION

EQUIPMENT GND

FIELD GND

DIAGNOSTIC
LED

2

CIRCUIT

CONNECTOR

HOT
SURFACE
IGNITER

OVERCURRENT

PROT.

DEVICE

IGNITER

TH

(3)

INTEGRATED
CONTROL MODULE

JUNCTION

BOX

LINE-H

XFMR-H

INT

E

GRA

T

ED CONTROL

MODULE

IN

TEGRA

T

E

D

CONTROL

MODULE

GND

DISCONNECT

L

N

OVERCURRENT

PROTECTION

DEVICE

BR

GY

RD

BL

BK

4.

IF

HEATING

AND

COOLING

BLOWER

SPEEDS

ARE

NOT

THE

SAME,

DISCARD

JUMPER

BEFORE

CONNECTING

BLOWER

LEADS. UNUSED

BLOWER

LEADS

MUST

BE

PLACED

ON

"PARK"

TERMINALS

OF

INTEGRATED

CONTROL

OR

TAPED.

3.

IF

ANY

OF

THE

ORIGINAL

WIRE

AS

SUPPLIED

WITH

THE

FURNACE

MUST

BE

REPLACED,

IT

MUST

BE

REPLACED

WITH

WIRING MATERIAL

HAVING

A

TEMPERATURE

RATING

OF

AT

LEAST

105

TERMINAL

SWITCH

(PRESS.)

5.

UNIT

MUST

BE

PERMANENTLY

GROUNDED

AND

CONFORM

TO

N.E.C.

AND

LOCAL

CODES.

PK

PINK

115

VAC

HOT

AND

PARK

TERMINALS

LINE-H

FLAME
SENSOR

FRONT

COVER

PRESSURE

SWITCH

N
O

C

GY

BK

PLUG

CONNECTION

FIELD

SPLICE

SWITCH

(TEMP.)

OR

24V THERMOSTAT

CONNECTIONS

GR

GND

115 VAC

24 VAC

BLOWER
COMPARTMENT
DOOR SWITCH
(OPEN WHEN

DOOR OPEN)

DOOR
SWITCH

BK

GND

L

N

WH

JUNCTION

BOX

1

OR

ID

BLOWER

PRESSURE
SWITCH

HEAT-H

GND

WH

RD

WH

GND

BURNER

COMPARTMENT

BLOWER

COMPARTMENT

NOTE

4

SEE

N
O

COOL-H

BK

(HI)

BR

BR

CAPACITOR

YL

WH

YL

BL

PU

RD

OR

PK

BK

WH

WH

BLOWER

INDUCED

DRAFT

MANUAL

RESET

AUXILIARY

LIMITS

(1)

IN

UPFLOW

BLOW ER

DECK

(2)

IN

C'FLOW

BLOW ER

HOUSING

C

FS

HI

HE

AT

-H

LO

HE

AT

-H

IGNITER

HOT

SURFACE

IND

IGN

EAC-H

AIR

CLEANER

ELECTRONIC

BLWR

CIRCULATOR

BLWR

ID

FLAME

SENSOR

115

VAC

TRANSFORMER

40

VA

24

VAC

GND

RO1

(5)

RO2

(11)

HLO

(1)

HLI

(7)

MVC (9)

GND (8)

TR (6)

OR

WH

WH

BL

YL

OR

RD

GR

BR

PK

PK

GY

WH

11

5

V

A

C

N
E

UT
RA
L

BK

BK

GY

24V

THERMOST

A

T

CONNECTI

O

NS

MICRO

TO

C

G

Y

W

R

2

WH

OR

BL

YL

OR

OR

GY

PK

RD

OR

GY

WH

XF
M

R

-H

TE
R

M

IN

A

L

S

GY

OR

GR

BR

1

2

3

12

11

10

9

8

7

6

5

4

°C.

USE

COPPER

CONDUCTORS

ONLY.

24 VAC

HUMIDIFIER

24

VAC

HUMIDIFIER

HUMIDIFIER

PSO

(4)

MVL(2)

PS

(10)

C

NO

C

NO

FRONT COVER
PRESSURE

SWITCH

ID BLOWER
PRESSURE

SWITCH

0

C

7

6

5

4

3

2

1

OFF

=

CONTROL

FAILURE

STEADY

ON

=

NORMAL

OPERATION

1

FLASH

=

2

FLASHES

=

PRESSURE

SWITCH

STUCK

CLOSED

3

FLASHES

=

PRESSURE

SWITCH

STUCK

OPEN

4

FLASHES

=

OPEN

HIGH

LIMIT

5

FLASHES

=

FLAME

SENSE

WITHOUT

GAS

VALVE

7

FLASHES

=

LOW

FLAME

SIGNAL

6

FLASHES

=

CONTINUOUS/RAPID

FLASHES

=

REVERSED

115

VAC

POLARITY

CONTROL

MODULE

INTEGRATED

FUSE

ON

OFF

2ND
STAGE
DELAY

MODE

HEAT
OFF
DELAY

FS

1

2

3

HI

OR

OR

PM

GAS

VALVE

C

HI

MVH (12)

FACTORY

SETTINGS

SHOWN

*

*

*

*

SEE
NOTE 6

COOL-H

TO

115VAC/

/60

HZ

POWER

SUPPLY WITH

PU

Y

6. TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS

WHILE IN

STANDBY

(NO THERMOSTAT INPUTS)

BK

LIN

E

NEUT

RALS

8

8

FLASHES

=

CHECK

IGNITER

OR

IMPROPER

GROUNDING

Advertising