29

GE Energy Gas Turbines

Mechanical Drive

(ISO conditions - natural gas - shaft output)

ISO RATED

HEAT RATE

EFFIC.

PRESSURE

EXHAUST

TURBINE EXHAUST

POWER

RATIO

FLOW

SPEED

TEMPERATURE

kW

shp

kJ/kWh btu/shp-h

%

kg/sec

Ibs/sec

RPM

°C

°F

PGT5

5,440

7,295

13,470

9,523

26.7

8.6

25.8

56.9

10,290

533

991

GE5

5,600

7,510

11,429

8,080

31.5

14.6

20.0

44.2

12,500

556

1,032

PGT10

10,660

14,295

11,060

7,819

32.5

13.8

42.3

93.3

7,900

488

910

GE10

11,982

16,068

10,822

7,651

33.3

15.5

46.9

103.3

7,900

480

896

PGT16

14,240

19,096

9,930

7,020

36.3

20.2

47.3

104.3

7,900

491

919

PGT20

18,121

24,300

9,867

6,975

36.5

15.7

62.6

137.9

6,500

475

887

PGT25

23,261

31,193

9,560

6,759

37.7

17.9

68.9

151.9

6,500

525

976

PGT25+

31,364

42,060

8,754

6,189

41.1

21.6

84.3

185.8

6,100

500

931

LM6000

43,679

58,575

8,600

6,080

41.9

27.9

126.5

280.0

3,600

455

853

MS5002C

28,340

38,005

12,470

8,816

28.8

8.8

123.4

274.1

4,670

517

963

MS5002E

32,000

42,913

10,000

7,070

36.0

17.0

102.0

225.0

5,714

511

952

MS5002D

32,580

43,690

12,239

8,653

29.4

10.8

141.4

311.7

4,670

509

948

MS6001B

43,530

58,380

10,825

7,653

33.3

12.0

140.0

309.0

5,111

544

1,011

MS7001EA

87,300 117,071

10,870

7,685

33.1

12.7

302.0

665.8

3,600

535

995

MS9001E

130,100 174,467

10,400

7,353

34.6

12.6

421.0

928.0

3,000

540

1,004

Advertising