7

C

h

a

djuStinG

l

imit

S

witCheS

and

f

oRCe

C

ontRolS

Adjustment 1:

A CLOSE ADJUSTMENT

On front panel of Power Head find adjusting screw

marked “CLOSE” (Figure MA-1) .

Gently turn screw counterclockwise until it stops .

Very little force is required to turn adjusting screw .

Press Wall Console to close garage door .

Observe if door stops at “CLOSE” limit switch .

(Figure MA-2) . If door is fully closed—adjustment is

finished . Go to “OPEN” Adjustment .

If door stops but is not fully closed,

a . Measure distance between bottom of door

and floor .

b . Move “CLOSE” Limit Switch that same distance

toward door .

If door stops and/or reverses before reaching the

“CLOSE” Limit Switch

a . Slightly increase CLOSE Force setting (clockwise) .

If door reverses after contacting floor, move Limit

Switch toward Power Head .

If door fails to move, check Safe-T-Beam® System .

See Troubleshooting Section, pages 10-11 .

Tighten Limit Switch Set Screw . Do not over-tighten

(strip) Limit Switch Set Screw .

B OPEN ADJUSTMENT

On front panel of Power Head find adjusting screw

marked “OPEN” (Figure MA-1) .

Gently turn screw counterclockwise until it stops .

Very little force is required to turn adjusting screw .

Press Wall Console to close garage door .

Observe if door stops at “OPEN” limit switch .

(Figure MA-2) . If door is fully open—adjustment

is finished .

If door stops but is not fully open,

a . Measure distance between bottom of door

top of door opening .

b . Move “OPEN” Limit Switch that same distance

toward Power Head .

If door stops before reaching the “OPEN”

Limit Switch

a . Slightly increase OPEN Force setting (clockwise) .

If door fails to move, see Troubleshooting Section,

pages 10-11 .

Tighten Limit Switch Set Screw . Do not over-tighten

(strip) Limit Switch Set Screw .

C Run Door Opener

Cycle opener a few times to double check settings .

Repeat adjustment steps as necessary .

WARNING:

• A moving garage door can cause serious injury or death.
• Keep the path clear.
• Position the ladder to the side of the Power Head so it is

clear of all moving parts of the Opener and the door .

• Set the door Opener to use the minimum force needed

to open the door .

NOTE

Little effort is required to turn the Force

Adjusting Knobs .

If the door stops moving while opening or

closing, adjust the Open Force or Close Force

Controls slightly clockwise (to slightly

increase the force) and retry the step .

The Open Force and Close Force Controls are to

be set to the minimum force necessary to

ensure the door smoothly opens and

closes completely .

Ensure the Carriage Assembly is engaged and is

between the two Limit Switches before

operating the Opener .

Figure MA-1 Making Force Adjustments

OPEN

CLOS

E

OPEN

CLOSE

FORCE

CONTROLS

m

aintenanCe

and

a

djuStmentS

Figure MA-2 Making Force Adjustments

OPEN

CLOSE

OPEN

CLOSE

Advertising