3-wire power cord installation, 4-wire power cord installation, Installation instructions electrical connections – GE EER3000 User Manual

Page 6: Warning, Cont.)

Advertising
background image

6

Installation Instructions

ELECTRICAL CONNECTIONS

(CONT.)

4-WIRE POWER CORD
INSTALLATION

WARNING:

The neutral wire of

the supply circuit must be connected to the
neutral terminal located in the lower center
of the terminal block. The power leads must
be connected to the lower left and the lower
right terminals of the terminal block. The 4th
grounding lead must be connected to the
frame of the range with the ground plate
and the ground screw.

Remove the 3 lower terminal screws from
the terminal block. Remove the ground
screw and ground plate and retain them.

Cut and discard the ground strap. DO NOT
DISCARD ANY SCREWS.

Insert the one ground screw into the power
cord ground wire terminal ring, through the
ground plate and into the frame of the range.

Insert the 3 terminal screws (removed earlier)
through each power cord terminal ring and
into the lower terminals of the terminal block.
Be certain that the center wire (white/neutral)
is connected to the center lower position of
the terminal block. Tighten screws securely
into the terminal block.

Skip to Step 8 and proceed with the installation.

E

D

C

B

A

5

3-WIRE POWER CORD
INSTALLATION

WARNING:

The neutral or ground

wire of the power cord must be connected
to the neutral terminal located in the
center of the terminal block. The power
leads must be connected to the lower left
and the lower right terminals of the
terminal block.

Remove the 3 lower terminal screws
from the terminal block. Insert the 3
terminal screws through each power cord
terminal ring and into the lower terminals
of the terminal block. Be certain that the
center wire (white/neutral) is connected
to the center lower position of the
terminal block. Tighten screws securely
into the terminal block.

DO NOT remove the ground strap
connection.

Skip to Step 8 and proceed with the
installation.

B

A

4

Ground
strap

Terminal
block
(appearance
may vary)

Neutral
terminal

Power cord

Before

After

Terminal
block

Terminal
block

Neutral
terminal

Neutral terminal

Ground strap

Ground
plate
(grounding
to range)

Ground
screw

Ground strap

Ground
plate

or

Advertising
This manual is related to the following products: