Step-by-step installation instructions – GE GXSF31E User Manual

Page 8

Advertising
background image

8

Step-by-step installation instructions.

Programming the Control

CONTROL SETTINGS REQUIRED

upon installation and

after an extended power outage.

NOTES:

WHEN THE TRANSFORMER IS PLUGGED INTO THE
ELECTRICAL OUTLET, 12:00 PM (flashing), and PRESENT
TIME
is displayed. Program the control as instructed below.

If

- - - is flashing,

use the UP

button to set the

correct model code as follows: SR22 for GXSF27E or F31 for
GXSF31E. If you pass by the correct code number, use the
DOWN

button. Then press the MODE button to accept

the correct model.

A “beep” sounds while pressing buttons for control
programming. One beep signals a change in the control
display. Repeated beeps mean the control will not accept
a change from the button you have pressed, and you should
select another button.

To program the control, you will use the UP

, DOWN

and MODE buttons.

Use the MODE button to select the desired control function.

SET PRESENT TIME OF DAY

1. Press the MODE button until PRESENT

TIME appears in the display.

2. Press UP

or DOWN

button to set.

The UP button advances the time; the
DOWN button moves the time in reverse.

2.

If the present time is between noon and midnight, be sure
PM shows in the display. If the present time is between
midnight and noon, be sure AM shows in the display.

NOTE: Each press of an UP

or DOWN

button changes

the time by one minute. Holding the button changes the time
at a rapid rate.

3. When the present time is correct, press MODE to accept.

SET WATER HARDNESS NUMBER

1. Press the MODE button until

HARDNESS appears in the display.

2. Press UP

or DOWN

button to set your water hardness

number in the display. DOWN decreases the hardness value.
UP increases the hardness value.

NOTE: Each press of a button changes the display by 1, between
1 and 25. Above 25, the display changes 5 at a time (25, 30, 35,
etc.). Holding a button in changes the numbers at a rapid rate.

3. When the display shows your water hardness (in grains per

gallon), press MODE to accept.

NOTE: If there is clear water iron in your water supply, you will
need to increase the hardness setting by 5 for each 1 ppm of
clear water iron in your water supply.

You can get the grains per gallon (gpg) hardness of your water
supply from a water analysis laboratory. If you are on a
municipal supply, call your local water department. Or call
GE Answer Center

®

to request a water hardness test kit. If your

report shows hardness in parts per million (ppm), simply divide
by 17.1 to get the equivalent number of grains per gallon.

SET RECHARGE (STARTING) TIME

1. Press the MODE button until

RECHARGE TIME appears in the display.

NOTE: A flashing 2:00 AM (factory default)
should show in the display. This is a good time for recharge
to start (takes about 2 hours) in most households because water
is not in use. HARD WATER is bypassed to house faucets
during recharge.

If no change is needed, go to step 3.

To change the recharge

starting time, follow step 2.

2. Press UP

or DOWN

button to set the desired recharge

start time. Be sure to observe the AM or PM as you did when
setting the time of day.

NOTE: Each press of a button changes the time by 1 hour.
Holding the buttons in changes the time at a rapid rate.

3. Press the MODE button to accept.

Advertising
This manual is related to the following products: