RS-232 SERIAL COMMUNICATION COMMANDS

Switching/Routing Binary Table

ASCII

RMT-4IR

Button

Binary

1

1

0011 0001

2

2

0011 0010

3

3

0011 0011

4

4

0011 0100

EDID Management Modes

All DIP switches inside the unit must be in their default OFF position. Use the ASCII
commands below to change the EDID modes. For a description of each mode please
see page 8.

ASCII

EDID Mode

m0

0

m1

1

m2

2

m3

3

m4

4

m5

5

m6

6

m7

7

IR Remote Channel Confi guration

All DIP switches inside the unit must be in their default OFF position. Use the ASCII
commands below to change the IR code channel. Please ensure that the IR remote
channel on the RMT-4IR matches any channel that is set by these commands. For a
description of the IR code channel confi guration please see page 6.

ASCII

Remote Channel

r1

1

r2

2

r3

3

r4

4