Installation of the warming drawer, Installation below wall ovens, Installation below a single oven – GE JTD910SBSS User Manual

Page 14: Installation below a double oven, Read these instructions completely and carefully

Advertising
background image

Installation of the warming drawer.

Read these instructions completely and carefully.

Installation Below Wall Ovens

When installed, the front face of the warming
drawer will be nearly flush with cabinetry doors
or drawer fronts.

Drawer overlaps will conceal cut edges on all
sides of the opening.

The rough opening for the drawer must be:

—Depth: 23

1

2

minimum from inside back to

front of cabinet frame.

—Width: 25

1

2

for 27

wide models

28

1

2

for 30

wide models.

—Height: 9

1

4

Allow 2

minimum between oven and drawer

cutouts for clearance of overlaps.

NOTE: If you are installing in frameless cabinets,
it may be necessary to install 1/2

wide cleats to

accept drawer mounting screws. See drawer to
find exact locations of mounting screws.

When installed under a wall oven:

Warming drawers are suitable for installation
below only certain specified wall oven models.
See the label attached to the top of the warming
drawer for suitable models.

NOTE: Electrical receptacle can be installed
as shown for countertop installations. Do not
install receptacle above the top of the warming
drawer cutout.

23

1

2

Min.

2x2 or 2x4 anti-tip
block against rear
wall 9” from floor
to bottom of block

1

Min. above toekick or adjust

to oven installation height

A

B

Oven

cutout

NOTE: Additional clearance between cutouts may
be required. Check to be sure that oven supports
above the warming drawer location do not obstruct
the required interior 23

1

2

depth and 9

1

4

height.

Installation below a single oven

2

Min

1

Min. above toekick

NOTE: Additional clearance between cutouts may
be required. Check to be sure that oven supports
above the warming drawer location do not obstruct
the required interior 23

1

2

depth and 9

1

4

height.

Installation below a double oven

Dimension A

Dimension B

27

Drawer

25

1

2

26

3

4

30

Drawer

28

1

2

30

2x2 or 2x4 anti-tip
block against rear
wall 9” from floor
to bottom of block

9

2

Min.

Allow 5/8”
overlap on
all sides

10

1

2

23

1

2

Min.

Allow 5/8

overlap

on all sides

A

Oven

cutout

23

1

4

10

1

2

B

9

9

1

4

23

1

4

9

1

4

Customer Service

Troubleshooting T

ips

Installation Instructions

Care and Cleaning

Operating Instructions

Safety Instructions

14

Advertising
This manual is related to the following products: