Amp draw meter, Notice – Grizzly G0445 User Manual

Page 25

Advertising
background image

G0445/G0582/G9962Z/9962ZX Wide Belt Sander

-23-

Amp Draw Meter

The amperage draw meter (

Figure 17) is located

above the control panel. Use the meter to monitor
the amperage draw on

the machine while per-

forming sanding operati

ons.

As a general rule, always start with a small
load and work your way up. DO NOT work your
machine to its maximum load, where you can
hear the motor lose RPM; instead, make multiple
passes or install a coarser grit paper.

Amp load will be directly affected by many factors
such as feed rate, depth of cut, wood type, sand-
paper grit, and workpiece width. If the amp load is
in the red load range, the machine is overloaded
and motor damage will occur. Keep the amp load
in the green range during operation.

Figure 17. Typical amp draw meter

and load chart.

NOTICE

DO NOT VOID WARRANTY! Keep the amp

draw within the GREEN load range shown

on the AMP LOAD CHART. If you operate

the sander in the RED load range, capacitor

or motor failure will occur and will not be

covered under warranty.

Advertising