Installation Preparation

3

PREPARE DISHW ASHER ENCLOSURE

The rough cabinet opening must be at least 24" deep

and 23-5/8" To Wide.

The

opening

should

be

to 35" max. height.

The dishwasher must be installed so that drain hose is

no more than 10 feet in length for proper drainage.

The dishwasher must be fully enclosed on the top,

sides and back, and must not support any part of the

enclosure.

CLEARANCES: When

installed into a corner ,

allow 2" min. clearance

between dishwasher and

adjacent cabinet, wall or

other appliances. Allow

25-5/8" min. clearance

from the front of the

dishwasher for door

opening. Figure 2

DRAIN REQUIREMENTS

Follow local codes and ordinances.

Do not connect

Do not exceed 10 feet distance to drain.

drain lines from other devices

to the dishwasher drain hose.

Dishwasher must be connected to waste line with an

air gap (not supplied) or 32" minimum high drain loop,

depending on local codes and ordinances to prevent

back flow into the dishwasher .

?Air gap must be used if waste tee or disposer connec-

tion is less than 18" above the floor to prevent siphoning.

DRAIN PREPARATION

The type of drain installation depends on answers to

the following questions:

Do local codes or ordinances require an air gap?

Will waste tee or disposer connection be less than

18" above the floor?

Will installation have a drain loop less than 32"

above floor?

If the answer to ANY of the 3 questions above is YES,

Method 1 MUST be used . Otherwise either Method 1

or Method 2 may be used. Figure 3 or Figure 4.

CAUTION:

An air gap MUST BE USED if the drain hose is connected

to waste tee or disposer lower than 18" above the floor.
Failure to provide the proper drain connection height

with air gap or 32" minimum, high drain loop will result

in improper draining of the dishwasher .

Figure 1

Figure 2

Figure 3

Figure 4

4

6

Cabinets

Square

and

Plumb

Floor MUST

be Even with

Room Floor.

Plumbing and Electric Service

Must Enter Shaded Area

32-1/2to 35"

Underside of

Countertop

to Floor

24"

Min.

Clearance for Door

Opening 2" Minimum

Countertop

Dishwasher

25-5/8"

Note:

Llation,

(32-1/2") counter

tops may

by

the

and

leveling legs.

18"

Min.

32"

Min.

32"

Min.

18"

Min.

Install waste tee or disposer and air gap according to

manufacturer

Manufacturer s

instructions.

CABINET PREPARATION

shaded areas shown in Figure 1 for the drain hose

connection. The hole should be smooth with no sharp

edges.

Method 1 Air Gap with Waste Tee or Disposer

Method 2 High Drain with Waste Tee or Disposer

Provide a method to attach drain hose to underside

of countertop.

24"

·

18"

Min.

Drill a 1-1/2 dia.Hole in the cabinet wall within the

Advertising