Generator, Product selector guide, Pr o tection c ontr ol monit oring & me tering – GE Generator Protection G650 User Manual

Page 2

Advertising
background image

MIG II

G650

G60

W650

3

GENERATOR

Product Selector Guide

16

G30

489

Overspeed

12

Q

Speed Switch

14

Q

Distance Backup

21

Q

Q

Overexcitation

24

Q

Q

Q

Synchronism check

25

Q

Q

Q

Q

Phase/Auxiliary Undervoltage

27P/A

P

P

P

P/A

P/A

Stator Ground (3rt Harmonic)

27TN

Q

Q

Q

Ground Undervoltage (Fundamental)

27GN

Q

Q

Sensitive Directional Power (F/R/LF)

32

Q

Q

Q

Q

Q

Bearing RTD

38

Q

Q

Q

Loss of Excitation Impedance or React. Power

40

Q

Q

Q

Q

Current Unbalance

46

Q

Q

Q

Q

Q

Q

Negative Sequence Overcurrent

50_2/51_2

Q

Q

Q

Q

Voltage phase reversal

47

Q

Q

Q

Q

Q

Inadvertent/Accidental Energization

50/27

Q

Q

Q

IOC, Ground/Neutral/Phase/Negative Sequence

50G/N/P/Q

P/N

G/N/P

G/N/P/Q

G/N/P/Q

G/N/P

G/N/P

IOC, Sensitive Ground

50SG

Q

Q

Q

Q

TOC, Ground/Neutral/Phase/Negative Sequence

51G/N/P/Q

P/N

G/N/P

G/N/P

G/N/P

G/N/P

G/N/P

TOC, Sensitive Ground

51SG

Q

Q

Q

Split Phase

50SP

Q

Q

Voltage Restraint Overcurrent

51V

Q

Q

Q

Q

Q

Breaker Failure

50BF

Q

Q

Q

Logic

Phase/Auxiliary/Neutral Overvoltage

59P/A/N

P/A/N

P/N

P

P/A/N

P/A/N

Ground Overvoltage

59GN

Q

Q

Q

100% Stator Ground

64G

Q

Q

Q

Current Directional, Ground/Neutral/Phase/Neg. Seq. 67P/G/N/Q

P/G/N

G

P/N/Q

P/N/Q

Out of Step Blocking

68

Q

Out of Step Tripping

78

Q

Q

Voltage Transformer Fuse Failure

VTFF

Q

Optional

Q

Q

Q

Under/Overfrequency

81U/O

3U & 3O

3U & 3O

2U & 2O

Q

Q

Anti-Islanding Protection/Rate of Change of Frequency

81R

Q

Q

Q

Lockout Functionality

86

Q

Q

Ground Differential

87N

Q

Q

Q

Q

Differential

87S

Q

Q

Group Differential

87T

Q

Monitoring of Reactive Power

Q

Q

Q

Remote Display

Q

Redundant Power Supply

Optional

Optional

Option

Non-volatile latches

Q

Q

Programmable Elements

Programmable Logic

Q

Q

Q

Q

Q

FlexElements™

Q

Q

Digital Inputs

2

Up to 32

Up to 32

7

80

80

Contact Outputs

5

Up to 16

Up to 16

6

64

64

Virtual Inputs/Outputs

Up to 32

Up to 32

32/64

32/64

Direct Inputs/Outputs

Up to 512

Up to 512

32

32

Trip/Close Coil Supervision

Optional

Optional

Trip

Trip/Close

Trip/Close

User-Programmable LEDs

Q

Q

Q

Q

Q

User-Programmable Push Buttons

Q

Q

Q

Q

User-Programmable Self Test

Q

Q

Selector Switch

Q

Q

Digital Counters

Q

Q

Q

Q

Q

Digital Elements

Q

Q

Q

Q

IRIG-B Input

Q

Q

Q

Q

Q

Analog Inputs/Outputs

Q

Q

Q

RTD Inputs

12

8

8

Power Factor

Q

Q

Q

Q

Q

Current

Q

Q

Q

Q

Q

Q

Voltage

Q

Q

Q

Q

Q

Voltage 3rd Harmonic

Q

Q

Power - Apparent, Real, Reactive

Q

Q

Q

Q

Q

Current, MW, MVA, Mvar Demand

Q

Q

Q

Energy

Q

Q

Q

Q

Q

Frequency

Q

Q

Q

Q

Q

Temperature

Q

Q

Q

User Programmable Fault Reports

Q

Q

Event Recorder - Number of Events

24

479

479

40

1024

1024

Oscillography - Cycles/Sampling Rate

24

128/64

128/64

64/12

93.5/16

93.5/16

Trip Counters

Q

Q

Q

Q

Q

Data Logger

Q

Q

Q

Q

Q

RS232/RS485 Ports

Q

Q

Q

Q

Q

Q

Ethernet Communications

Q

Q

Q

Q

Q

Fiber Optic Port

Optional

Optional

Q

Q

GE Modem

ModBus Protocol

Q

Q

Q

Q

Q

Q

ModBus User Map

Q

Q

Q

Q

Q

Q

DNP3 Protocol

Q

Q

Q

Q

Q

EGD Protocol

Q

Q

Peer-to-peer communication (Goose)

Q

Q

Q

Q

IEC 60870-104

Q

Q

Q

Q

IEC 61850 Protocol

Q

Q

Q

Q

Simple Network Time Protocol

Q

Q

Q

PR

O

TECTION

C

ONTR

OL

MONIT

ORING & ME

TERING

FEATURES

DEVICE

MIG

W650

G650

489

G30

G60

C

OMMUNICA

TIONS

* For the most current comparison list, access us online at:

www.GEMultilin.com/selector/generator.pdf