SITE REQUIREMENTS

16

4. BUILDERS OPENING

To make installation easier make the opening larger than

the minimum requirements where possible.

B

A

FRONT

C

Appliance

Dim A

Dim B

Dim C

16"

420

560

360

22"

570

620

360

24"

620

620

360

26"

670

620

360

28"

720

620

360

Appliance

Dim A

Dim B

Dim C

16"

420

510

360

22"

570

560

360

24"

620

560

360

26"

670

560

360

Standard Height

Low Lintel

Many fireplace openings have a supporting lintel. Remove

the covering plaster to identify it's position before starting any

constructive work. Do not remove constructional lintels without

making provision to support the remaining structure of the

building.

The appliance must not form any part of the supporting

structure.

4.1 The chimney/flue must have a sealed connection to the

appliance flue spigot.

4.2 The structure of the builders opening will reach high

temperatures. Use insulating blockwork to reduce the heat

transfer to the external walls, in particular the area of the

chimney breast above the opening.

4.3 Take care when finishing the chimney breast and

surrounding area. The conducted and convected heat

emitted by the appliance could be high enough to crack

normal plaster. Use a high temperature plaster, or face

the area with a suitable high temperature plasterboard.

New plaster should be fully dried before the appliance is

used, or cracking could occur.

If you are in any doubt about your ability to produce a

safe opening contact your Stovax dealer for professional

advice.

5. FIRE SURROUND CLEARANCES

If the appliance is to be fitted with a fire surround, use

the minimum clearances, see Diagram below, between

any point of the appliance and any combustible material.

Stovax produce a selection of surrounds and details can be

obtained from your local supplier.

150mm

300mm

150mm

PR8105

5.1 We recommend you obtain expert advice before

proceeding with work of this nature.

5.2 Some finishes may discolour with heat and some lower

quality products may distort, or crack, when in use.

If stone / granite / marble or any other natural material

is used to construct the fire surround, or any part of it,

provision should be made for expansion and movement

of the parts due to heating and cooling.

If you are in any doubt about the installation

requirements, or suitablity of fire surrounds contact your

Stovax dealer.

5.3 All fire surrounds should be suitable for use with solid fuel

heating products.