Valve specifications – GE Autorol 255 Valve / 400 Series User Manual

Page 27

Advertising
background image

27

260 Troubleshooting

Valve Specifications

Working Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20-120 psi (1.38 - 8.27 bar)
Standard 12 Volt Transformer Input Electrical Rating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115V 60 Hz
Optional 12 Volt Transformer Input Electrical Rating . . . . . . . . . . . . . . . . . . . 115V 50 Hz, 230V 50 Hz,

230V 60 Hz, 100V 60 Hz, 100V 50 Hz

Operating Ambient Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 °F to 120 °F (1 °C to 49 °C)
Operating Water Temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 °F to 100 °F (1 °C to 38 °C)

Problem

Possible Cause

Solution

1. No water flow

display when water
is flowing.

a. Bypass valve in bypass.

b. Meter probe disconnected

or not fully connected to
meter housing.

c. Restricted meter turbine

rotation due to foreign
material in meter !

d. Defective meter probe.

a. Shift bypass valve to not-in-

bypass position.

b. Fully insert probe into meter

housing.

c. Remove meter housing, free

up turbine and flush with
clean water. Turbine should
spin freely. If not, replace
meter. (Contact dealer.)

d. Replace meter cable (Contact

dealer.)

2. Continuous

regeneration.
Camshaft does not
stop at the end of
regeneration.

a. Misaligned optical sensor.

a. Replace optical sensor.

(Contact dealer.)

3. Run out of soft

water between
regenerations.

a. Improper regeneration.

b. Incorrect salt setting.

c. Incorrect hardness or

capacity settings.

d. Water hardness has

increased.

e. Restricted meter turbine

rotation due to foreign
material in meter !

a. Repeat regeneration, making

certain that correct salt
dosage is used.

b. Set salt control to proper level.

See salt setting chart.

c. Set to correct values. See

Programming section.

d. Set hardness to new value.

See Programming section.

e. Remove meter housing, free

up turbine and flush with
clean water. Turbine should
spin freely; if not, replace
meter. (Contact dealer.)

Advertising
This manual is related to the following products: