Dimensions and Installation Information (in inches)
Additional clearances—vent terminal
These clearances are applicable to both
concentric termination and non-concentric vent
exhaust terminations.
• Avoid termination locations near a dryer vent.
• Avoid termination locations near

commercial cooking exhaust

FLUe INSTALLATIoN - CoNDeNSATe DRAIN
HORIZONTAL TERMINATION WITH A CONDENSATE DRAIN

Concentric Vent Piece equivalent Length

Straight

1 ft (per foot length)

90˚ elbow

6 ft each

45˚ elbow

3 ft each

Total vent length = straight ft + 90˚ elbows x 6 ft + 45˚ elbow x 3ft

Note: Vent dimensions = up to 5 3/4 inches. Please read vent supplier's

installation manual for specific dimensions.

VeRTICAL TeRMINATIoN (condensate collector

required in all installations)

Vent Length Calculations
Maximum System performance is achieved at a vent length of 21
equivalent feet or less. The system is capable of 41 equivalent feet length if
required, but this reduces system performance. For vent length calculations,
a 90˚ elbow counts as 6 feet and a 45˚ elbow counts as 3 feet—see the