Generac Portable Products 5500EXL Extended Life Generator

7

To avoid engine problems, the fuel system should be

emptied before storage of 30 days or longer. Drain the

gas tank, start engine and let it run until the fuel lines

and carburetor are empty. Use fresh fuel next season.

See “Storage” on page 12.
Never use engine or carburetor cleaner products in the

fuel tank or permanent damage may occur.
To add fuel:
• Clean area around fuel fill cap, remove cap.
• Slowly add “UNLEADED” regular gasoline to fuel

tank. Leave about a 1/2" space in the fuel tank for

fuel expansion (Figure 5). Do Not overfill fuel tank.

• Install fuel cap and wipe up any spilled gasoline.

OPERATING THE

GENERATOR

CAUTION

! Never start or stop unit with

electrical loads connected AND with the

connected devices turned ON.

Starting the Engine

• Disconnect all electrical loads from the generator.
• Open the fuel shut-off valve (Figure 6).

• Set the Run/Stop switch to “Run” position.
• Make sure the Idle Control switch is in “Off” position.
• Move engine choke to “Full” choke position

(Figure 7).

For electric start:
• Press electric start button until engine cranks and

starts.

For manual start:
• Pull slowly on recoil handle until you feel some

resistance. Then pull rapidly to start engine. Return

recoil slowly, Do Not let it “snap back”.

Figure 7 — Choke Positions

Figure 5 — Fuel Tank Air Space

Figure 6 — Fuel Shut Off Valve