GE Monogram ZBD1850NII User Manual

Zbd1850nii, Ge monogram, 18" dishwasher

Advertising
background image

ZBD1850NII

GE Monogram

®

18" Dishwasher

For answers to your Monogram,

®

GE Profile

or

GE

®

appliance questions, visit our website at

ge.com or call GE Answer Center

®

service,

800.626.2000.

Specification Created 6/08

150050

Dimensions and Installation Information (in Inches)

• The dishwasher must be installed so that the drain hose is

no more than 10 feet in length for proper drainage.

• The dishwasher must be fully enclosed on the top, sides

and back, and must not support any part of the enclosure.

ClearanCeS

:

When installed into a corner, allow 2" min. clearance
between dishwasher and adjacent cabinet,wall or other
appliances. Allow 25-5/8" min. clearance from the front of
the dishwasher for door opening.

aDa-Compliant ZBD1850nII:

Installation below 34"-high countertops
A reduced-height installation (32-1/2" min.) beneath a
34" countertop can be accomplished by removing the
front leveling legs. The rear legs should be screwed in
flush with the bottom support, as shipped. The front of
the dishwasher must be shimmed to level it. Water and
electrical must be routed through the back wall.

electrical requirements
The dishwasher must be supplied with 120V, 60Hz, and
connected to an individual properly grounded branch
circuit protected by a 15- or 20-amp circuit breaker or
time-delay fuse.

Clearance for Door

Opening 2" Minimum

Countertop

Dishwasher

25-5/8"

Installation Information:
Before installing, consult installation instructions packed
with product, or available at Monogram.com, for current
dimensional data.

Listed by

Underwriters

Laboratories

As an EnErgy StAr

®

partner, gE has determined

that this product meets the

EnErgy StAr guidelines

for energy efficiency.