Specification Revised 1/08

130714

Monogram.

ZKD910BF/SF/WF – GE Monogram 27" Warming Drawer

For answers to your Monogram,

®

GE Profile

or

GE appliance questions, visit our website at

GEAppliances.com or call

GE Answer Center

®

service, 800.626.2000.

Undercounter Installation (in inches)

Note: When installing warming drawer with a cooktop,

allow a 2" minimum from cooktop burner box bottom to

top of cut-out.
Important Installation Note:

Must provide anti-tip brace at the back of the cabinet and

at the top of the cutout.
Optional Accessories:
ZXD27B
– 3/4" wood panel trim kit

*Note: When installing the warming drawer below a

cooktop, a solid barrier must be installed at 1” from the

lowest point of the bottom of cooktop burner box to the

top of cutout. Use any solid material such as 1/4” thick

plywood. Allow at least 1/4” air gap between the barrier

and the top of the warming drawer. See label on top of the

warming drawer for approved cooktop models.

Electrical

Outlet 16" Max.

From Left Side

Installation Below

a Drawer

23-1/2 Min.

Solid Barrier

1/4

Air Gap

25

1-1/2 Cabinet Top

36

Countertop

Height

1 Min.*

28-1/2

9-1/4

Electrical Outlet 42" Max.

From Right Side

Install a Solid Barrier

Below a Cooktop

See Note

Electrical Outlet

Flush With Side

of Cabinet 7" Max.

9

Install

2x4 or 2x2

Anti-Tip Block

Against Rear

Cabinet Wall

9" From Floor

to Bottom

of Block

7

Install a Solid Barrier

and a 1/4" Air Gap

Above Warming Drawer

• When installed, the front face of the drawer will be nearly flush

with adjacent cabinetry doors.

• Drawer overlaps will conceal cut edges on all sides of the opening.

The rough opening for the drawer must be:

–Depth 23-1/2" min. from inside back to front of cabinet frame.

–Width 25-1/2" for 27" wide models, 28-1/2" for 30" wide models.

–Height 9-1/4"

• 5" min. above floor or 1" above toekick. 23-1/4" from floor to bottom

of cutout is recommended for under countertop installation.

Installation below a cooktop:

Warming drawers are approved for installation below only certain

specified cooktop models. See the label attached to the top of the

warming drawer for approved models. A solid barrier and air gap

between cooktop and warming drawer is required. See Note above.

Installation below a cabinet drawer:

The warming drawer may be installed beneath a cabinet drawer. In

this installation, a solid barrier should be installed above the warming

drawer to block access. Use any solid material such as 1/4" thick

plywood. Allow at least 1/4" air gap between the barrier and the

top of the warming drawer. Observe the 5" min. above the floor or 1"

above the toekick minimum installation height.
Note: If you are installing in frameless cabinets, it may be necessary

to install 1/2" wide cleats to accept drawer mounting screws. See

drawer to find exact locations of mounting screws.

Side to Side Installation:

Install two warming drawers in separate cutouts. Allow 2" min.

between cutouts.

2

Min.

Side to Side Installation