WheelHouse™ 5550 Watt Generator

RECEPTACLES

120 Volt AC, 20 Amp, Duplex

Receptacle

Each receptacle (Figure 9) is protected against overload by
a push–to–reset circuit breaker.

Use each receptacle to operate 120 Volt AC, single–phase,
60 Hz electrical loads requiring up to 2,400 watts (2.4 kW)
at 20 Amps of current. Use cord sets that are rated for
125 Volt AC loads at 20 Amps (or greater).

120/240 Volt AC, 30 Amp, Locking

Receptacle

Use a NEMA L14–30 plug with this receptacle. Connect a
4–wire cord set rated for 250 Volt AC loads at 30 Amps (or
greater) (Figure 10).You can use the same 4–wire cord if
you plan to run a 120 Volt load.

This receptacle powers 120/240 Volt AC, 60 Hz, single
phase loads requiring up to 2,775 watts of power at
23.1 Amps for 120 Volts; 5,550 watts of power (5.55 kW)
at 23.1 Amps for 240 Volts.The outlet is protected by a
push–to–reset circuit breaker.

• NEVER attempt to power a device requiring more amperage

than generator or receptacle can supply.

• DO NOT overload the generator. See “Don’t Overload

Generator”.

Receptacles may be marked with rating value greater
than generator output capacity.

CAUTION

Figure 9 — 120 Volt AC, 20 Amp Duplex Receptacle

Figure 10 — 120/240 Volt AC, 30 Amp Receptacle

4-Wire Cord Set

240V

120V

120V

W (Neutral)

X (Hot)

Y (Hot)

NEMA L14-30

Ground (Green)