TROUBLESHOOTING

Problem

Engine is running, but no AC

output is available.

Engine runs good but bogs

down when loads are

connected.

Engine will not start; or starts

and runs rough.

Engine shuts down during

operation.

Engine lacks power.

Engine “hunts” or falters.

Cause

1. Circuit breaker is open.

2. Poor connection or defective cord

set.

3. Connected device is bad.

4. Fault in generator.

1. Short circuit in a connected load.

2. Generator is overloaded.

3. Engine speed is too slow.

4. Shorted generator circuit.

1. Dirty air cleaner.

2. Out of gasoline.

3. Stale gasoline.

4. Spark plug wire not connected to

spark plug.

5. Bad spark plug.

6. Water in gasoline.

7. Overchoking.

8. Low oil level.

9. Excessively rich fuel mixture.

10. Intake valve stuck open or closed.

11. Engine has lost compression.

1. Out of gasoline.

2. Low oil level.

3. Fault in engine.

1. Load is too high.

2. Dirty air filter.

3. Engine needs to be serviced.

1. Choke is opened too soon.

2. Carburetor is running too rich or

too lean.

Solution

1. Reset circuit breaker.

2. Check and repair.

3. Connect another device that is in

good condition.

4. Contact Generac service facility.

1. Disconnect shorted electrical load.

2. See “Don’t Overload the

Generator” on page 11.

3. Contact Robin service facility.

4. Contact Generac service facility.

1. Clean or replace air cleaner.

2. Fill fuel tank.

3. Drain gas tank and fill with fresh

fuel.

4. Connect wire to spark plug.

5. Replace spark plug.

6. Drain gas tank; fill with fresh fuel.

7. Put choke lever to “no choke”

position.

8. Fill crankcase to proper level.

9. Contact Robin service facility.

10. Contact Robin service facility.

11. Contact Robin service facility.

1. Fill fuel tank.

2. Fill crankcase to proper level.

3. Contact Robin service facility.

1. See “Don’t Overload the

Generator” on page 11.

2. Replace air filter.

3. Contact Robin service facility.

1. Move choke to halfway position till

engine runs smoothly.

2. Contact Robin service facility.