GE EZ2 Series User Manual

Page 11

Advertising
background image

2.10

Recovery

The machine flow specifications listed below are based on 77°F (25°C).

Table 2.4

E2/EZ2 - Series

Flow Specifications for

Machines

7

2100/

2535

33 - 50%

95 - 98%

1.8 (0.40)

1.8 - 1.2

(0.41 - 0.82)

1400/

1690

33 - 50%

95 - 98%

1.2 (0.27)

1.2 - 0.8

(0.27 - 0.54)

1125

33 - 50%

95 - 98%

0.9 (0.20)

0.9 -0.6

(0.20 - 0.13)

620/

750

33 - 50%

95 - 98%

0.5 (0.11)

0.5 - 0.3

(0.11 - 0.07)

0375

33 - 50%

95 - 98%

0.3 (0.07)

0.3 - 0.2

(0.07 -0.14)

E2/EZ2-Series

Units

Recovery Range

Rejection Rate

Permeate Rate

gpm (m

3

/h)

Concentrate Rate

gpm (m

3

/h)

Advertising
This manual is related to the following products: