background image

G1028Z/G1029 Dust Collector

-11-

Figure 3.

Mounting collector to base.

Figure 4.

Mounting outlet to collector body.

Collector Body

The collector body includes the fan assembly,
switch, and motor which are preassembled at the
factory. Set the collector body on top of the base
plate so the intake portion is near the edge of the
base plate and the bolt holes are lined up as
shown in

Figure 3.

Secure the collector body to

the base plate with four (4)

5

16

"-18 x

1

2

" hex bolts

provided.

Outlet

The outlet can now be attached to the main col-
lector body. Insert the

rubber gasket

between

the collector and lower outlet flange and secure
using eight (8)

5

16

"-18 x

1

2

" hex bolts provided.

See Figure 4.