Jvb98sh – ge profile, 36" telescopic downdraft system, Venting duct information plan the ductwork – GE JVB98SH User Manual

Page 2

Advertising
background image

JVB98SH – GE Profile

36" Telescopic Downdraft System

TM

6" Round
Straight

3-1/4" x 10"
Straight

6"
90

°

Elbow

6"
45

°

Elbow

3-1/4" x 10"
90

°

Elbow

3-1/4" x 10"
45

°

Elbow

3-1/4" x 10"
45

°

Elbow

6" Round
to 3-1/4 x 10"
Transitions

3-1/4" x 10"
to 6" Round
Transition

6" Round
to 3-1/4 x 10"
Transitions
90

°

Elbow

3-1/4" x 10"
to 6" Round
Transition
90

°

Elbow

6" Round
Wall Cap
with Damper

3-1/4" x 10"
Wall Cap
with Damper

p

6" Round
Roof Cap

6" Round
Roof Vent

Duct Pieces

Equivalent Length*

Duct Pieces

Equivalent Length*

1 ft. (per foot length)

1 ft. (per foot length)

15 ft.

9 ft.

16 ft.

5 ft.

24 ft.

7 ft.

5 ft.

20 ft.

12 ft.

21 ft.

27 ft.

20 ft.

24 ft.

SHOULD NOT EXCEED 100 EQUIVALENT FT.
*Equivalent length of duct pieces are based on actual test conducted by

GE Evaluation Engineering and reflect requirements for good venting
performance with a downdraft rated at 500 CFM

Venting Duct Information

Plan the Ductwork

1. This downdraft blower system is designed for use with 3-1/4" x 10"

ductwork (can be transitioned to 6" round). Two different discharge
directions are available with side-to-side adjustment for the accurate
alignment of ductwork.

2. For best performance: choose the ducting option which allows the shortest

length of ductwork and a minimum number of elbows and transitions.
Check location of floor joists, wall joists, wall studs, electrical wiring or
plumbing for possible interference.

Steps to Determine Flexible Ducting’s Equivalent Length

1. Measure the actual amount of offset (Maximum 3" recommended).

The effect upon airflow is dependent upon the amount of offset.

2. Calculate the equivalent ducting allowances using:

(__in. offset) x (14 Ft. per inch)
=__Ft. equivalent length.

1. Ensure that the total equivalent length of ducting does not exceed the

maximum recommendation of 150 feet.

Left discharge
(as shipped)

Right
discharge

Specification Created 7/03